10 enEmission values for sound and vibration (Two-figure – specifications as per ISO 4871)Sound emission WSG10-115T WSG14-125T WSG14-150T WSG14-70ET WSS14-125TA-weighted emission pres-sure power level measuredat the workplace LpA(re 20 μPa),in decibels 85 85 85 85 85Measuring uncertainty KpA ,in decibels 3 3 3 3 3Measured A-weightedsound power level L wA(re 1 pW), in decibels 96 96 96 96 96Measuring uncertaintyKwA , in decibels 3 3 3 3 3C-weighted peak soundpressure level measured atthe workplace LpCpeak,in decibels 99 99 101 101 99Measuring uncertaintyKpCpeak, in decibels 3 3 3 3 3VibrationsVibration emission value(triax vector sum) determi-ned according to EN 60745Mean vibrational value forangle grinding , inm/s2ft/s2 5.0155.0154.513.54.513.55.015Mean vibrational value forsanding with sanding sheet, inm/s2ft/s2 2.57.52.57.52.57.52.57.52.57.5Measuring uncertainty K, inm/s2ft/s21.54.51.54.51.54.51.54.51.54.5REMARK: The sum of the measured emission value and respective measuring inaccuracy rep-resents the upper limit of the values that can occur during measuring.Wear ear protection!Measured values determined in accordance with the corresponding product standard.h,AGh,DS3 41 01 121 21 0.book Seite 10 Montag, 22. August 2011 1:11 13