19Performance Data SheetSmartWater™ Filtration System³GE MWF CartridgeThe concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissiblelimit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International againstNSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below.The following pharmaceutical reduction claims have not been certi¿ed by NSF International or the state of California.Claims tested and veri¿ed by independent laboratory:ContaminantReduction AvHUDJH,Q¾XHQW16)VSHFL½HGChallenge ConcentrationAvg %ReductionAverage ProductWaterConcentrationMax PermissibleProduct WaterConcentrationNSF ReductionRequirementsNSFTest ReportAtenolol 978 ng/L N/A 99.5% 5.0 ng/L N/A N/A J-00121587Fluoxetine 907 ng/l N/A 99.4% 5.4 ng/L N/A N/A J-00121587Ibuprofen 885 ng/L N/A 94.1% 52.3 ng/L N/A N/A J-00121588Progesterone 1097 ng/L N/A 99.5% 5.0 ng/L N/A N/A J-00121589Trimethoprim 415 ng/L N/A 99.5% 2.0 ng/L N/A N/A J-00121587It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.See Installation Manual for Warranty information.Application Guidelines/Water Supply ParametersService Flow 0.5 gpm (21.9 lpm)Water Supply Potable WaterWater Pressure 40-120 psi (2.8-8.2 bar)Water Temperature 33°F-100°F (0.6°C-38°C)Note: While the testing was performed under standard laboratory conditions,actual performance may vary.Replacement Cartridge: MWF. For estimated costs of replacement elementsplease call 1-800-626-2002 or visit our website at www.geapplianceparts.com.WARNINGTo reduce the risk associated with ingestion of contaminants:• Do not use with water that is microbiologically unsafe or of unknown qualitywithout adequate disinfection before and after the system. Systems certL¿edfor cyst reduction may be used on disinfected water that may contain ¿lterablecysts. EPA Establishment Number 10350-MN-005.NOTICETo reduce the risk associated with property damage due to water leakage:• Read and follow use instructions before installation and use of this system.• Installation and use MUST comply with all state and local plumbing codes.• Do not install if water pressure exceeds 120 psi (8.2 bar). If your water pressureexceeds 80 psi, you must install a pressure-limiting valve. Contact a plumbingprofessional if you are uncertain how to check your water pressure.• Do not install where water hammer conditions may occur. If water hammerconditions exist you must install a water hammer arrester. Contact a plumbingprofessional if you are uncertain how to check for this condition.• Do not install on hot water supply lines. The maximum operating watertemperature of this ¿lter system is 100º F (38º C).• Protect ¿lter from freezing. Drain ¿lter when temperatures dropbelow 33ºF (0.6ºC).• must be replaced every 6 months at therated capacity, or sooner if a noticeable reduction in ÀRw rate occurs.For conditions of use, health claims certified by the California Department of PublicHealth, and replacements, see performance data sheet. California Departmentof Public Health Certification #05-1698. The contaminants or other substancesremoved or reduced by this water filter are not necessarily in all users’ water.Capacity 300 Gallons (1,135 Liters). Contaminant Reduction Determined by NSF testing.Substance Testedfor Reduction AvHUDJH,Q¾XHQW16)VSHFL½HGChallenge ConcentrationAvg %ReductionAverage ProductWaterConcentrationMax PermissibleProduct WaterConcentrationNSF ReductionRequirementsNSFTest ReportChlorine Taste and Odor 2.0 mg/L 2.0 mg/L ± 10% 97.5% 0.05 mg/L N/A J-00077703Nominal Particulate&ODVV,WRP 7,833,333 pts/mL At least 10,000 particles/mL 99.7% 18,617 pts/mL N/A J-00077704Cyst* 101,000 cysts/L Minimum 50,000 cysts/L 99.99% 1 cyst/L N/A J-00100036Asbestos 47 MF/LWR¿EHrV/¿EHrsgrHDWHUWKDQPLQOHQJWK >99% 0)/ N/A J-00077707Atrazine 0.009 mg/L 0.009 mg/L ± 10% 94.5% 0.0005 mg/L 0.003 mg/L N/A J-00077708Benzene 0.016 mg/L 0.015 mg/L ± 10%± 96.7% 0.0005 mg/L 0.005 mg/L N/A J-00077717Carbofuran 0.08 mg/L 0.08 mg/L ± 10% 98.7% 0.001 mg/L 0.04 mg/L N/A J-00077718Endrin 0.007 mg/L 0.006 mg/L ± 10% 97.1% 0.0002 mg/L 0.002 mg/L N/A J-00100039Lead @ pH 6.5 0.152 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00077722Lead @ pH 8.5 0.148 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00077723Lindane 0.002 mg/L 0.002 mg/L ± 10% 99.0% 0.00002 mg/L 0.0002 mg/L N/A J-00077726Mercury @ pH 6.5 0.0058 mg/L 0.006 mg/L ± 10% 93.2% 0.0004 mg/L 0.002 mg/L N/A J-00100037Mercury @ pH 8.5 0.0061 mg/L 0.006 mg/L ± 10% 93.2% 0.0004 mg/L 0.002 mg/L N/A J-00092355P-Dichlorobenzene 0.222 mg/L 0.225 mg/L ± 10% 99.8% 0.005 mg/L 0.075 mg/L N/A J-00077729Tetrachloroethylene 0.015 mg/L 0.015 mg/L ± 10% 96.7% 0.0005 mg/L 0.005 mg/L N/A J-00082184Toxaphene 0.015 mg/L 0.015 mg/L ± 10% 93.2% 0.001 mg/L 0.003 mg/L N/A J-000777302,4-D 0.218 mg/L 0.210 mg/L ± 10% 99.5% 0.0009 mg/L 0.07 mg/L N/A J-00085470*Based on the use of Cryptosporidium parvum oocysts.Tested and cerWL½ed by NSF Internationalagainst NSF/ANSI Standard 42 andStandard 53 in model GE MWF for thereduction of the claims speci½Hd on theperformance data sheet.REPLACEMENTELEMENT