26255/440i TroubleshootingProblem Possible Cause Solution1. Control will notdraw brine.a. Low water pressure.b. Restricted drain line.c. Injector plugged.d. Injector defective.e. Air check valve closesprematurely.a. Set pump to maintain 20 psiat softener.b. Change drain to removerestriction.c. Clean injector and screen.d. Replace injector. (Contactdealer.)e. Put control momentarily intobrine/slow rinse. Replace orrepair air check if needed.(Contact dealer.)2. System using moreor less salt thanregenerant setting.a. Foreign matter incontroller causingincorrect flow rates.a. Remove brine control andflush out foreign matter.Manually position control tobrine/slow rinse to cleancontroller (after so doingposition control to "purge” toremove brine from tank).3. Intermittent orirregular brinedraw.a. Low water pressure.b. Defective injector.a. Set pump to maintain 20 psiat softener.b. Replace injector. (Contactdealer.)4. No conditionedwater afterregeneration.a. No salt in brine tank.b. Injector plugged.c. Air check valve closesprematurely.a. Add salt to brine tank.b. Clean injector and screen.c. Put control momentarily intobrine/slow rinse. Replace orrepair air check if needed.(Contact dealer.)5. Controlbackwashes orpurges atexcessively low orhigh rate.a. Incorrect drain controllerused.b. Foreign matter affectingcontroller operation.a. Replace with correct sizecontroller. (Contact dealer.)b. Remove drain controller andclean ball and seat.