– 25 –Air Tunnel InletThe Air Tunnel Inlet must be removed to access theDamper Motor, damper door switch, and damperdoor assembly.To remove the Air Tunnel Inlet:1. Remove the control panel. (See Control PanelRemoval.)2. Remove the Phillips-head screw from the topright corner of the oven frame.3. Remove the Air Tunnel Cover. (See Air TunnelCover.)4. Remove the Phillips-head screw that attachesthe power cord to the metal shield.5. Remove the Phillips-head screw that attachesthe power cord ground wire to the oven frame.6. Disconnect wiring to the filter board and thePhillips-head screw that attaches the fi lter boardground wire to the oven frame. (See Noise Filter.)Power Cord(Continued Next Page)7. Remove the rear Phillips-head screw underneaththe ventilation motor receptacle.8. Using long nose pliers, squeeze the tabs on eachside and push the ventilation motor receptaclefrom the Air Tunnel Inlet.9. Disconnect the wires attached to the VentilationMotor Capacitor. (See Ventilation MotorCapacitor.)10. Disconnect the stirrer motor wire harness. (SeeStirrer Assembly.)11. Disconnect the wires attached to the MagnetronFan Motor. (See Magnetron Fan Assembly.)12. Disconnect the wire harnesses attached to thePower Supply Board. (See Power Supply Board.)13. Remove the Phillips-head screw that attachesthe power supply board ground wire to the ovenchassis.14. Remove 6 Phillips-head screws that attach theAir Tunnel Inlet to the oven.Vent Receptacle