21Level I ProgrammingThe AvantaPure control can be quickly programmed byfollowing the sequential procedure. Level I programparameters are those that can be accessed by pressingthe UP or DOWN buttons.• Model Number: Select a model from the table basedon the application. Review Table 1 and determineyour model number before you start.• Time of Day: Includes PM indicator. Can be set todisplay as a 24-hour clock. See Level ll programming• Day of Week: Set to actual day of the week.• Time of Regeneration: Fully adjustable. Default is2:00 AM.Note: When the control is set up for a twelve-hour clocka PM indicator will illuminate when the displayed time is inthe PM hours. There is no AM indicator.Table 1This table is for reference only. Your model number shouldbe set by an AvantaPure Water Treatment Professionalbased on your specific application requirements.ModelNumberTankDiameterResin Cu. Ft.Total SaltDosagelbsTotalCapacityKilograinsInjectorType47 10 x 401.00 Ft 3 2.5 10,000 5 Bump48 10 x 401.00 Ft 3 3.5 12,000 5 Bump49 10 x 401.00 Ft 3 8.5 20,000 5 Bump50 10 x 401.00 Ft 3 13 22,000 5 Bump51 10 x 441.25 Ft 3 3 13,000 5 Bump52 10 x 441.25 Ft 3 11 25,000 5 Bump53 10 x 441.25 Ft 3 16 28,000 5 Bump54 10 x 541.50 Ft 3 4.0 16,000 5 Bump55 10 x 541.50 Ft 3 5.0 18,000 5 Bump56 10 x 541.50 Ft 3 12.5 30,000 5 Bump57 10 x 541.50 Ft 3 19 33,000 5 Bump