REINSTALLING THE REFRIGERATOR DOORSReverse steps 1 through 4 to reinstall refrigerator, followdetails below for critical alignments.Reinstall center hinge first and torque the screws to65 in-lbs. With the LH door at 90º to the front ofthe case, lower the refrigerator door onto the centerhinge. Ensure that the door and hinge align correctly.Rotate doors closed and make sure moveable centersealing portion of the door aligns with the striker. If thedoor will not self-close after reinstalling, remove door,turn door upside down, check alignment mark andarrow; (there is an alignment mark on the door closuremechanism It corresponds to an alignment mark onthe bottom end cap. Rotate door closure mechanism toalign mark and arrow, reinstall door).Securely tape the door shut with masking tape orhave a second person support the door. Reinstall thetop hinge and torque the screws to 65 in-lbs.Be sure to reinstall the ground wire and strain relief tothe top hinge.Reinstall the hinge cover. Note: Ensure wires are notpinched or under screw bosses before tightening screws.REMOVE THE REFRIGERATOR DOORS (cont)Note: for proper installation later, please follow the next stepcarefully.Fresh Food doors to be REMOVED and INSTALLEDopened at 90 with case front.REMOVE OPPOSITE DOORFollow the same procedure on the oppositedoor. There are no wires or water lines on the oppositesideREMOVE CENTER HINGE (if necessary)Remove the 3/8ļscrews securing the center hinge to the cabinet.Use T20 driver to remove outboard screw25FLift up & offcenter hingeOpen Doorto 90°4Installation InstructionsINSTALLING THE REFRIGERATOR (cont.)A5BLoosen Outer screwsRemovecenterscrewCalign marksUnderside OFFresh Food DoorIf door cannot be installed at 90° follow steps below:1. If space or model limits opening door to less than 180°, then:a) Remove door, carefully turn door upside down.b) Check alignment of door closure mechanism shaft onunderside of door. The flats on the shaft shouldcorrespond to alignment tab on plastic ring or markon bottom end cap.c) If shaft is not aligned to tab/mark, using 5/32” Allenwrench, rotate door closure mechanism shaftcounterclockwise for right door and clockwise for leftdoor. Then align flat with tab/mark.d) Install the door at 90°.D