22Error code chartError code Fault condition ActionE 10 Communication failure. - EEPROM Clear code, exit mode and start dryer. Ifthe error persists, replace the control board.E 11 Communication failure. - Checksum Clear code, exit mode and start dryer. Ifthe error persists, replace the control board.E 12 Communication failure. - Memory Clear code, exit mode and start dryer. Ifthe error persists, replace the control board.E 24 Shorted control thermistor. Remove wires from the control thermistor.Measure resistance of the thermistor. If thereading is not 50K (+/-10%), replacethermistor. If the reading is within 50K(+/-10%) check wiring between thermistorand electronic control. If good, replaceelectronic control.E 25 Open control thermistor. Remove wires from the control thermistor.Measure resistance of the thermistor. Ifthe reading is not 50K (+/-10%), replacethermistor. If the reading is within 50K(+/-10%) check wiring between thermistorand electronic control. If good, replaceelectronic control.E4A The drying time has exceeded program Press Pause Cancel and Select buttons fortime for that cycle. 6 seconds to exit test modes. Position cycleselector to NORMAL, temperature selector toHIGH HEAT, and touch START. Check for anything that would extend dry times, such as noheat, restricted vent, blower fan blade brokenor loose, dryer installed in closet with soliddoor, or bad connection in moisture sensorbar circuit or dirty bars. If dryer operatesnormally but code returns, replace electroniccontrol.E 5B No heat. Refer to flow chart “dryer not heating properly.”E 68 One of the keys (buttons) is Enter function test mode and perform keystuck closed (active). (button) test to determine which button is atfault. Carefully free the key and perform the testagain. If button is free but the key stuck codestill exists, replace electronic control.E 8C High limit thermostat has tripped too many Check for blocked lint filter, blockedtimes in a certain amount of time. exhaust, air leaks around air duct, brokenblower fan blades, worn or loose drum seals,dryer installed in closet with solid doors ordoor seal not correctly seated.E AF Microcontroller has been reset Clear code, exit mode and start dryer. Ifby internal Watchdog timer. problem persists, replace electronic control.