The improper connection of the equipment-grounding conductor can result in electricshock. Check with a qualified electrician orservice representative if you are in doubtthat the appliance is properly grounded.Do not modify the plug provided with theappliance; if it will not fit the outlet, havea proper outlet installed by a qualifiedtechnician.WARNING5Cabinet Preparation and Wire Routing• The wiring may enter the opening from either side,rear or floor within the shaded area illustratedabove in Figure E and defined in Figure A.• Cut a 1-1/2" maximum diameter hole to insert theelectrical cable. Permanent wiring connectionsmay pass through the same hole as the drainhose and hot water line, if convenient. Hole edgesmust be smooth and rounded. If the cabinet wall ismetal, the hole edge must be covered with a cordprotector.NOTE: Power cords with plug must pass through aseparate hole.PREPARE ELECTRICAL WIRINGElectrical Requirements• This appliance must be supplied with 120V, 60 Hz.,and connected to an individual properly groundedbranch circuit, protected by a 15- or 20-amperecircuit breaker or time-delay fuse.• Wiring must be 2 wire with ground.• If the electrical supply does not meet the aboverequirements, call a licensed electrician beforeproceeding.Grounding Instructions – Permanent ConnectionThis appliance must be connected to a grounded-metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuitconductors and be connected to the equipment-grounding terminal or lead on the appliance.Grounding Instructions – Power Cord ModelsThis appliance must be grounded. In the event of amalfunction or breakdown, grounding will reducethe risk of electric shock by providing a path ofleast resistance for electric current. This applianceis equipped with a cord having an equipment-grounding conductor and a grounding plug. The plugmust be plugged into an appropriate outlet that isinstalled and grounded in accordance with all localcodes and ordinances.White18"6"24"from Wall3"fromCabinetAlternateReceptacleLocationGroundBlack1-1/2" Dia. Hole (Max.)18"6"ReceptacleLocationAreaFigure EInstallation Preparation – Electrical SupplyFOR PERSONAL SAFETY: Remove house fuseor open circuit breaker before beginninginstallation. Do not use an extension cord oradapter plug with this appliance.Electrical Connection to DishwasherElectrical connection is on the right front ofdishwasher.• For permanent connections, the cable must berouted as shown in Figure E. The cable must extenda minimum of 24" from the rear wall.• For power cord connections, install a 3-pronggrounding-type receptacle in the adjacent cabinetrear wall, between 6" and 18" from the opening, 6"to 18" above the floor as shown in Figure E.Hole Diameter1-1/2" MaximumCordProtector(Providedwith PowerCord Models Only)Metal Cabinet WallPARA SEGURIDAD PERSONAL: Retire elfusible de la casa o abra el interruptor decircuitos antes de empezar la instalación.No use un cable de extensión o enchufeadaptador con este aparato.La conexión incorrecta del conductorde conexión a tierra del equipo puederesultar en choque eléctrico. Consulte conun electricista calificado o representantede servicio si tiene dudas de la conexióna tierra del aparato. No modifique elenchufe que se suministra con el aparato;si no calza en el tomacorrientes, hagaque un técnico calificado le instale untomacorrientes adecuado.ADVERTENCIAWARNINGWARNINGADVERTENCIA