DIAGNOSTIC STATUS CODESSX TRANSISTOR CONTROL Page 36October 1998TRACTIONSTATUS CODEDESCRIPTION OF STATUS CAUSE OF STATUS INDICATION-92 USER DEFINED STATUS CODESee instructions for TruckManagement Module for details.This status code will be displayed when the voltage atthe respective terminal of the TMM or Pump LogicCard is at zero volts.MEMORY RECALLYES CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAMCircuits validforTractionController&PumpControllerSYMPTOMStatus code flashes “on and off”.POSSIBLE CAUSEUser defined status code is displayed by switchclosure or motor brush sensor closure tonegative.•= See GEH-TMM7A, “Truck ManagementModule Instructions” for OEM defined statuscodes for complete corrective action required.Terminal 4 (TMM7A) is shorted to negative.Plug P15 (pump) is shorted to negative.Defective input switch (shorted).Defective TMM card.Defective pump card.1 3 4 52 7 96 8 10 11 12 131415P15NEGSC92WHEN TMM7A CARD IS USEDNEGUSER SWWHEN SR Series PUMPCONTROL IS USEDUSER SWTRACTIONSTATUS CODEDESCRIPTION OF STATUS CAUSE OF STATUS INDICATION-93 USER DEFINED STATUS CODESee instructions for TruckManagement Module for details.This status code will be displayed when the voltage atthe respective terminal of the TMM or Pump LogicCard is at zero volts.MEMORY RECALLYES CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAMCircuits validforTractionController&PumpControllerSYMPTOMStatus code flashes “on and off”.POSSIBLE CAUSEUser defined status code is displayed by switchclosure or motor brush sensor closure topositive.•= See GEH-TMM7A, “Truck ManagementModule Instructions” for OEM defined statuscodes for complete corrective action required.Terminal 5 (TMM7A) is shorted to positive.Plug P3 (pump) is shorted to positive.Defective input switch (shorted).Defective TMM card.Defective pump card.1 3 4 52 7 96 8 10 11 12 131415POSSC93WHEN TMM7A CARD IS USEDPOSUSER SWP3USER SWWHEN SR Series PUMPCONTROL IS USED