DIAGNOSTIC STATUS CODESSX TRANSISTOR CONTROL Page 37October 1998TRACTIONSTATUS CODEDESCRIPTION OF STATUS CAUSE OF STATUS INDICATION-93 USER DEFINED STATUS CODESee instructions for TruckManagement Module for details.This status code will be displayed when the voltage atthe respective terminal of the TMM or Pump LogicCard is at zero volts.MEMORY RECALLYES CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAMCircuits validforTractionController&PumpControllerSYMPTOMStatus code flashes “on and off”.POSSIBLE CAUSEUser defined status code is displayed by switchclosure or motor brush sensor closure topositive.•= See GEH-TMM7A, “Truck ManagementModule Instructions” for OEM defined statuscodes for complete corrective action required.Terminal 6 (TMM7A) is shorted to positive.Plug P4 (pump) is shorted to positive.Defective input switch (shorted).Defective TMM card.Defective pump card.1 3 4 52 7 96 8 10 11 12 131415POSSC93AWHEN TMM7A CARD IS USEDPOSUSER SWP4USER SWWHEN SR Series PUMPCONTROL IS USEDTRACTIONSTATUS CODEDESCRIPTION OF STATUS CAUSE OF STATUS INDICATION-94 USER DEFINED STATUS CODESee instructions for TruckManagement Module for details.This status code will be displayed when the voltage atthe respective terminal of the TMM or Pump LogicCard is at zero volts.MEMORY RECALLYES CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAMCircuits validforTractionController&PumpControllerSYMPTOMStatus code flashes “on and off”.POSSIBLE CAUSEUser defined status code is displayed by switchclosure or motor brush sensor closure topositive.•= See GEH-TMM7A, “Truck ManagementModule Instructions” for OEM defined statuscodes for complete corrective action required.Terminal 8 (TMM7A) is shorted to positive.Plug P5 (pump) is shorted to positive.Defective input switch (shorted).Defective TMM card.Defective pump card.1 3 4 52 7 96 8 10 11 12 131415SC94WHEN TMM7A CARD IS USEDPOSP5USER SWWHEN SR Series PUMPCONTROL IS USEDPOSUSER SW