Document #MPOELSVC0504 Page 23SERVICE PROCEDURESDoor Micro Switch Service / Removal1. Open the oven door.2. Locate and remove the 2 machine screws locatedin the upper LEFT side of the cavity frame. (Thesescrews are just RIGHT of the upper door post onthe cavity door frame.)3. Remove both screws. DO NOT TOUCH THECOUNTERSINK SCREW.4. Remove the 2 screws holding the door micro switchcover. This is located on the front LH side of theoven top panel.5. There will be a small bracket exposed. This bracketholds the 2 micro switches. Pull the bracket towardyou.6. Upper switch on bracket is SW2, lower switch isSW1.7. Replace requiredmicro switch.8. Reinstall doorswitches and bracketand screws.9. Test door switchactivation /operation asindicated inDIAGNOSTICMODE.Oven Temperature Probe Service/RemovalThe probe is located on the interior RIGHT rear sideof the oven cavity.1. To first gain access to the temperature probe, removethe oven racks, rack support guides and baffle plateRemove the 2 screws holding the probe in placeDO NOT REMOVE THE PROBE at this point.2. The wires for the probe are located behind theRIGHT side panel.3. To gain access, remove the screws holding the panelin place.4. Pull the panel towards the back of the oven toremove.5. Cavity probe is located ABOVE and to the RIGHTof the cavity motor.6. Disconnect the 2 BROWN probe wires at thetemperature probe.7. The probe can now be removed from inside theoven.����������������������������������������������������������������������������������