Post Installation Configuration & Checkout190-01499-02 GTX 3X5 Transponder TSO Installation ManualRev. 9 Page 6-26.3 Configuration Mode and SettingsNOTEScreenshots are for illustrative purposes only. They do not imply the shown setting(s) should be used inany installation.System and interface settings are shown in configuration mode and are unique to the GTX 3X5 installation. Theconfiguration settings are stored in internal memory. If connected, the configuration module stores configurationsettings. The optional GAE module operates as a configuration module. In this section, configuration instructionsare for panel mount units. To configure remote units refer to section 6.11.To enter configuration mode on a panel mount unit, push and hold ENT and apply power.• Push and hold OFF until the unit powers off to exit configuration mode.• Push FUNC to cycle through the group pages.• Push 8 or 9 to scroll up or down on the page without an active field selected.• Push CRSR to access items on the page.• Push 8 or 9 to cycle through the selections of an item on the page.• Push ENT to move within the page with a field highlighted or to accept setting.• Push CLR to move to previous selection on the page.• Push FUNC to exit the page.