/8done in accordance with this manual.WARNING: DO NOT INSTALL THIS INSERT IN A SLEEPING ROOM.2. Where lesser clearances are desired, consult your local authority as regulations may vary regardingthe use of clearance reducing devices. Listed wall and floor shields are available to reduceclearances, and most building codes provide information on materials which may be used to reduceclearances (see Figure 1).3. Maintain at least the minimum clearances to combustible material as specified in this manual.Clearances are measured to the nearest part of the insert (i.e. top edge on the side). Clearances toany combustibles, when measured directly out from the front, must be a minimum of 48" (1219mm).4. Maintain at least the minimum floor protection for combustible floor materials as specified in thismanual. Floor protection to the front is to be measured from the fuel loading door opening.5. Osburn recommends that you install a listed smoke detector or alarm in your home. Normaloperation of the insert will have no effect on the detector or alarm.6. The insert is to be connected only to a lined masonry chimney and masonry fireplace conformingto building codes for use with solid fuel. Do not remove bricks or mortar from the existingfireplace when installing the insert.7. Minimum chimney size is 6" (152mm) diameter. Maintain a 15' (4.5m) minimum overall heightmeasured from the base of the appliance. Chimneys should be inspected to check fordeterioration and to determine if they meet the minimum requirements, and be upgraded ifnecessary. The chimney must extend at least 3' (914mm) above the roof and at least 2' (610mm)above the highest point within an area of 10' (3m) of the chimney.8. Do not use makeshift compromises during installation, as they could create a safety hazard and a firecould result.9. DO NOT CONNECT THIS APPLIANCE TO THE CHIMNEY OR FLUE SERVING ANOTHERAPPLIANCE.2.4 Installation Instructions1. Inspect the fireplace according to the safety information and fireplace requirements and have itcleaned and/or upgraded as necessary.2. If the installation of the unit renders the existing damper control inaccessible, it will be necessary toeither secure the damper wide open or remove it entirely. An inaccessible damper, which may close,could cause smoke to enter the room. This creates a potential health hazard.3. CONNECTOR INSTALLATION: A flue connector may provide acceptable performance, however,we recommend the use of a chimney liner to ensure satisfactory performance. Slip connectors forcontinuous liners should also be installed. Use Listed Chimney Liners – UL1777, CAN/ULC-S635.4. ATTENTION INSTALLER: When positioning the unit in a fireplace opening prior to the flue