13Connecting high voltage accessories: European model in.yeFor the connection to the 0�250 inch terminals, the high voltage accessories must be provided with female quickconnect terminals, straight and non-insulated for all types of connections, including the ground� Only 230 V accessoriesmay be connected to the corresponding terminals of the printed circuit of the in�ye� Refer to the following tables forcorrect connections� Note that all female terminals must be correctly and completely seated on the printed circuitterminals for proper current ratings�This table shows typical connections� OEMs may have a different connection scheme�* Ozonator and circulation pump can be combined on the same output via the optional splitter PP1�ConnectionsCirculation pump* (A1)Voltage 230 VGreen / ground P51Black / line K4-PWhite / common P60Light (12 V AC, 1A Max.)Always on P34Relay P35Direct output 1 (A0 / Floatingconnector) (in.ye-5-CE only)Voltage 230 VGreen / ground P47Black / line P32White / common P56Pump 1 (A2)(in.ye-5-CE)Voltage 230 VGreen / ground P50Black / low speed K6-PRed / high speed K3-PWhite / common P59Pump 3 (A4)(in.ye-5-CE only)Voltage 230 VGreen / ground P48Black / line K6-PWhite / common P57Pump 1 (A3)Voltage 230 VGreen / ground P49Black / low speed K2-PRed / high speed K1-PWhite / common P58Pump 2 (A2)(in.ye-3-CE)Voltage 230 VGreen / ground P50Black / low speed K2-PWhite / common P59