L NAPCO Security Systems X GEM-P816 Installation InstructionsWI994C 3/04 !Page 51CP-01 Quick Reference Chart--SIA False Alarm ReductionFeature Description Programming AddressLocationCP-01 FEATURES are enabled with one global selection in the panel. Enabled in EZ ProgrammingExit Delay. Minimum allowed programmable Exit Delay time is 45 seconds. Default is 60 seconds. If an attempt is made tochange the Exit Delay time to less than 45 seconds the time will be entered as 60 seconds. The maximum programmable time is255 seconds. The panel uses the existing programmable by zone feature "Entry/ Exit 1" to comply with CP-01. At least oneEntry/Exit zone must be programmed for each area. The factory program enables Zone 1 as Entry/Exit and the option to pro-gram any zone as Entry/Exit is given in the Easy Program Menu. The existing programmable Entry and Exit delay times are alsoused. The factory program sets the Exit Time Delay as 60 seconds and Entry Time Delay as 30 seconds. These same timesare entered when "Enable CP-01 Features" is selected in the Easy Program Menu.0000 (Pre-existing)When "Enable CP-01 Limits" (Address 1062, Bit 3) is enabled, the panel will sound an audible egress sequence when it isarmed Away (with interior zones not bypassed). The keypad mini-sounder will beep once every second during the beginning exitdelay and beep rapidly the last 10 seconds of exit delay to indicate exit urgency. If the panel is armed Stay (with interior zonesbypassed) the keypad mini-sounder is silent and the exit time is double the programmed time. If "Enable CP-01 Limits" (Address1062, Bit 3) is NOT enabled, the panel will NOT sound an audible egress sequence. Note: This feature affects the operation of"Zone ANDing" as follows: If "Enable CP-01 Limits" is enabled, any Zone in a Group will only activate an alarm and send a reportONCE. After the Zone has reported, it will remain in the Group and may still initiate the Zone ANDing sequence.1062, Bit 3 (see Note 1)(1062 ∑ ∑ ∑ 4 ∑ ∑ ∑ ∑)*(1062 ∑ 8 )**Exit Time Restart. This option allows for the following scenario before the end of the Exit Time: a violation of an entry/exit zone,a restore, and a second violation of an entry/exit zone restarts the Exit Time. The panel does not allow the Exit Time to be re-started more than once. The default setting for this option is enabled. Restart is event logged.1062, Bit 0 (see Note 1)(1062 1 ∑ ∑ ∑ ∑ ∑ ∑ ∑)*(1062 ∑ 1 )**Sound Alarm On Exit Error. An Exit Error sequence is initiated if an entry/exit zone is violated at the expiration of the Exit Time."Exit Error" Central Station Reporting Code is located at address 0348.1062, Bit 1 (see Note 1)(1062 ∑ 2 ∑ ∑ ∑ ∑ ∑ ∑)*(1062 ∑ 2 )**Unvacated Premises. Convert from Away to Stay based on no egress through exit door Ödefault is enabled. (GEM-P816panel--This feature is Automatic Interior Bypass/Easy Exit).The panel uses the existing programmable feature "Auto Interior Bypass/Easy Exit". This feature must be enabled in CP-01installations. This feature is enabled in the factory program and it is also enabled when "Enable CP-01 Features" is selected inthe Easy Program Menu.0722, Bit 0(0722 1 ∑ ∑ ∑ ∑ ∑ ∑ ∑)*(0722 ∑ 1 )**Report Digital Dialer Exit Error/Recent Closing. A Recent Closing transmission is sent if an alarm occurs within two (2) min-utes after the expiration of the Exit Time. If the user number is available, it is included in the Recent Closing transmission."Recent Close" Central Station Reporting Code is located at address 0349. Note: Address 1062, bit 1 must also be set to en-able this feature.1062, Bit 2 (see Note 4)(1062 ∑ ∑ 3 ∑ ∑ ∑ ∑ ∑)*(1062 ∑ 4 )**Entry Delay. Entry Delay time is 30 second minimum, default is 30 seconds. If an attempt is made to change the Entry Delaytime to less than 30 seconds the time will be entered as 30 seconds. The maximum programmable time is 255 seconds. Thepanel uses the existing programmable by zone feature "Entry/ Exit 1" to comply with CP-01. At least one Entry/Exit zone must beprogrammed for each area. The factory program enables Zone 1 as Entry/Exit and the option to program any zone as Entry/Exitis given in the Easy Program Menu. The existing programmable Entry and Exit delay times are also used. The factory programsets the Exit Time Delay as 60 seconds and Entry Time Delay as 30 seconds. These same times are entered when "EnableCP-01 Features" is selected in the Easy Program Menu.0001, 0002(Pre-existing feature)Progress Annunciation. Entry urgency annunciation must be different than the alarm mini-sounder. Requires KeypadSounder on Alarm on all non-fire zones. Locations 0529, 0584, 0639 and 0694.Feature in EZ ProgrammingDisarm. The panel will silence the keypad entry delay tones and alarm annunciation on the first press of a keypad digitfor 2.5 seconds.New Panel OperationSelect Alarm Output for Keyfob Chirp. Normally the chirp on a keyfob arm/disarm is transmitted to the PGM output. Se-lecting "CHIRP BURG BELL OUTPUT" causes the "Bell" to chirp instead of the PGM on remote Arming.The panel uses the existing programmable feature "Chirp Output on Keyfob Arm/Disarm" (Address 720, bit 6). This featuremust be programmed in a CP-01 installation if a GEM-KEYF is used in the system. The feature is selected in the factory pro-gram and is enabled if "Enable CP-01--Enabled" is selected in the Easy Programming Menu.0721, Bit 7 (see Note 3)(0721 ∑ ∑ ∑ ∑ ∑ ∑ ∑8 )*(0721 8 ∑ )**Enable CP-01 Limits. When address 1062 bit 3 is enabled, three time limits are enabled as per the SIA CP-01 standards: (1) Ifthe Exit Delay time is programmed for less than 45 seconds, the enabled Exit Delay time will be set to 60 seconds; (2) If the EntryDelay time is programmed for less than 30 seconds, the enabled Entry Delay time will be set to 30 seconds; and (3) If an at-tempt is made to change the Abort Delay to less than 15 seconds or more than 45 seconds the time will be entered as30 seconds. (4) Enables Exit Delay sounder. (5) Doubles Exit Delay time when arming Stay due to Silent Exit.1062, Bit 3 (see Note 1)(1062 ∑ ∑ ∑ 4 ∑ ∑ ∑ ∑)*(1062 ∑ 8 )**Abort Window Disarm. The panel will silence the keypad entry delay tones and alarm annunciation on the first press of a key-pad digit for 2.5 seconds.New Panel/Keypad FeatureAbort Annunciation after Disarming. Default is enabled. If the panel is disarmed during Abort Delay, the keypad will enunci-ate abort. "Alarm Cancelled" is displayed on keypad LCD for RP1/K1 and RP2/K2, and "C" in the 7-segment display for the RP3/K3.New Panel/Keypad FeatureReport Cancel Window. When the system is in alarm and the user disarms in an attempt to Cancel within a minimum of 5 min-utes after abort timeout, a Cancel Report will be sent. If Cancel Report is enabled by entering a cancel time (and Abort Delay byzone) Cancel will enunciate on the keypad if the system is disarmed during the Cancel Window. The existing programmableoption Report Cancel Window must be programmed for at least 5 minutes in a CP-01 installation. When "Enable CP-01" Fea-tures is selected in the easy program menu, this time is set to 7 minutes.Address 1179Duress Feature. The existing programmable option "Enable Global Ambush" must not be enabled in CP-01 installations. It isnot enabled in the factory program and is not enabled when Enable CP-01 Feature is selected in the Easy Program Menu.Pre-existing feature