GEM-P816 Installation InstructionsPage 23NAPCO Security SystemsRALARM INDICATION If programmed to silence an alarm, enter a valid User Code and press the U button.The keypad must have permission to disarm the alarm (Alarm, Pulse Alarm, PGM1 or PGM2 outputs) from the specificarea. This can be done through the PC Quickloader software, Area Features Screen or Area Bell Control. See Pro-gramming Instructions (WI995 or WI1182) for specific address locations.Should a burglary alarm occur, the red ARMED LED will flash, and the display will alternately read “ALARM”, then thezones violated. Disarm the panel; the display will read “ALARM” and will continue to indicate the violated zones until theC button is pressed or the panel is armed once again.FUNCTION MODE/DEALER PROGRAM MODEThe keypad can provide a wide assortment of utility functions as summarized in the Keypad Function Mode. Thefunctions are displayed in a prompting “YES/NO” format. To skip a function, answer NO (press the PRIOR/NO button);to select and execute a function, answer YES (press the P button or the U button). The complete function list isprovided here in its normal displayed sequence. However, since not all functions are designed for all systems (orintended for all users), only functions that are applicable and active are displayed. (For example, if no zones arebypassed, “DISPLAY ZN BYPASSED” will not appear). Furthermore, functions that are intended for use by the installer orservicer will not be displayed. Note: Functions may be manually scrolled forward or backward using the A andB buttons, respectively.To return to normal keypad operation, press the C button. (The keypad will automatically return to its normaloperating mode if no activity is detected for longer than one minute). Note: Due to space constraints, GEM-RP2ASe2/GEM-K2AS message displays are abbreviated.Remember: (1) Functions that are not active, not programmed and/or not applicable to the user's authority level will besuppressed and will not display. (2) Press the PRIOR/NO button to skip a function; press the NEXT/YES button toexecute it. (3) The GEM-RP2ASe2/GEM-K2AS displays abbreviated messages that autoscroll.DISPLAY ZN FAULTSPress the NEXT/YES button to identify all unsecured zones (within the keypad's area) while disarmed. PressNEXT/YES button to scroll through the zones. Manually bypassed zones will be indicated when displaying status.DISPLAY ZN BYPASSEDPress NEXT/YES button to display zones that have been deactivated. Press NEXT/YES button to scroll throughthe zones.DISPLAY ZN DIRECTORYPress NEXT/YES button to display a list of all programmed zone descriptions in the keypad area. Press NEXT/YES button to scroll through the zones. To return to the system, press the C button at any time.ACTIVATE BELL TESTPress the NEXT/YES button to activate the burg relay output (while disarmed) for about 2 seconds. If the device doesnot sound, it may be defective.DISPLAY FIRE ALARMTo display Fire Zone(s) in alarm, access DISPLAY FIRE ALARM and scroll through the zones using the NEXT/YES button. Correct the problem, then press the C button to restore the "SYSTEM READY" condition.DISPLAY FIRE TRBLTo display Fire Zone(s) in trouble, access DISPLAY FIRE TRBL and scroll through the zones using the NEXT/YESbutton. Correct the problem, then press the C button to restore the "SYSTEM READY" condition.ACTIVATE CHIMEPress the NEXT/YES button to sound a tone at the keypad when a Chime Zone is violated. The duration of the tone isprogrammable. To turn off the Chime Mode, press the NEXT/YES button at the DEACTIVATE CHIME function. Note:Chime is disabled for protected zones while armed. Never Armed zones (such as a driveway sensor) will continue to