GEM-P816 Installation InstructionsPage 27NAPCO Security SystemsRGLOSSARYDisplayed messages shown are for the GEM-RP1CAe2 and/or GEM-K1CA keypads. Otherkeypad messages are similar but abbreviated. Refer to the GEM-P816 Programming Manu-als (WI995 and WI1182) for specific address numbers.Abort Delay (Do not program for UL Applications)An Abort Delay is a delay period that allows cancellation of the central-station report by disarming the control panel before a reportis sent. If Enable CP-01 Limits is enabled, the Abort Delay is 30 seconds (which cannot be removed but can be adjusted to withinthe CP-01 specification of 15-45 seconds). In addition, if an attempt is made to change the Abort Delay to less than 15 seconds ormore than 45 seconds, the time will be entered as 30 seconds. If enable CP-01 Limits is NOT enabled, the factory delay time willbe set at 30 seconds, and can be deleted or increased to 255 seconds. Refer to "Enable CP-01 Limits" in this glossary. Enableprogram zones for Abort Delay and select an Abort Delay Time. Also, a Pre-Alarm Warning may be selected for zones allowing akeypad indication of alarm with no alarm outputs or central station reporting for the duration of abort delay time.AC Failure; AC-Fail Report DelayIf AC power is removed from the control panel, "AC POWER FAIL/E01-00 SERVICE" will display at the keypad with a flashing "SYS/TRBL"icon as a reminder and a pulsing sounder. Press C to silence the sounder; the "SYS/TRBL" icon reminder will remain on and"SYSTEM READY" will appear in the display. If a User Code is entered within 5 minutes, the panel may be armed. After 5 minutes, thesystem trouble will again display.AC Failure may be programmed to activate the Alarm Output, Pulsed Alarm Output, PGM1 Output, PGM2 Output, Relay Outputsand/or report to a central station by selecting AC Fail Report Event Telco 1, AC Fail Report Restore Telco 1, AC Fail Report EventTelco 3, AC Fail Report Restore Telco 3. The AC Trouble Fail Display, AC Fail Logging, and AC Fail Report to the central stationwill occur immediately unless an AC Fail Report Delay is programmed.Access Control; Access Control (Panel Access) on PGM2 Output; PGM2 Output Access Control Time; Panel AccessNote: The GEM-P816 has not been evaluated by UL for compliance with UL294 (Access Control Systems).The PGM2 Output can be programmed to activate for a programmable period of time (2 to 254 sec.). This allows it to be used foraccess functions such as opening and closing a garage door, or remotely activating an electric door strike through an RB1000 relay.This is achieved by programming a new Keyfob option, Access on PGM2 Output, into the Aux. 1 or Aux. 2 option locations on theWireless Keyfobs screen. This feature also requires a valid time to be entered into the PGM2 Output Access Control in the TimeSelection Screen.If Access Control on PGM2 Output is selected, entering the Access Code (see User Code Programming in Easy Menu Driven ModeProgramming) while disarmed will trip the panel's PGM2 Output. (This is commonly used to activate a door strike for the purposesof remotely unlocking a door). Each keypad is individually selected for Panel Access. Also program PGM2 Output Access ControlTimeout. Note: Do not program the PGM2 Output as an output on alarm. Do not program Keyfob Chirp on PGM2, unless EnableBell Output on RF Arming is selected also.Panel Access is selectable for any keypad 1–7 by selecting the Panel Access option for those keypad numbers (1–7) that are torespond to the User Code. However, if the Access Option is programmed, the code will no longer function as an Arm/Disarm Code.Entering a valid code at the keypad will cause the PGM2 output on panel to turn on for the programmed time. The RB1000 Relaymay be used to activate a door strike, and power to the door strike should be supplied from an independent power source.Access Number for Outside Line (CS Receiver Telephone Number Access)Some subscribers will have a telephone system that requires one digit to access an outside line. The first dial tone encountered(prior to the access number) may have a frequency that is different from that of the accessed dial tone (440Hz). One or more 4-second Pre-Dial Delay "D"s may be entered before any of the CS Receiver Telephone Numbers instead of a dial tone withfrequency "E". See Pre-Dial Delay; Telephone Numbers. (Note: The panel features automatic dial-tone detection and will normallynot require any "E"s. To disable this feature, see CS System Report Options in the Programming Instructions WI995 and WI1182).If the subscriber's system uses an access number, contact the telephone-equipment supplier to find out if a dial tone other than440Hz is received prior to dialing the access number. If the communicator must delay before dialing the access number instead ofattempting to recognize the dial tone, find out how many 4-second delays must be programmed.Alarm on Day Zone See Day ZoneAlarm Outputs (See Wiring Diagram for UL requirements); Alarm Output DurationThe GEM-P816 has three outputs: Alarm (Burg. & Fire), PGM1 and PGM2. The following table summarizes wiring for signaling analarm in typical installations. See Time Selection for timeout durations.