L NAPCO Security Systems X GEM-P9600 Programming Instructions!Page 17WI 1185 6/03Central Station Receiver 1 Telephone Number• Enter telephone number of up to 16 digits.• Press 1 through 9 for digits 1ñ9; G 0 for a zero and 0 for a blank (ï).• Press G 1 through G 5 for letters BñF, respectively.• Pre-Dial Delay = ìDî (G 4); Dial-Tone Detection = ìEî (G 5).• Press U to save and press the NEXT/YES button to proceed.NOTE: Central Station Receiver 2 and 3 Telephone Numbers must be entered in Direct Address Program-ming. See CS Receiver Options.Central Station Receiver 1 Account Number• Enter an account number of up to four digits.• Press 0 through 9 for digits 0ñ9, and G 0 for a blank (ï).• Press U to save and press the NEXT/YES button to proceed.NOTE: Central Station Receiver 2 and 3 Account Numbers must be entered in Direct Address Program-ming. See CS Reporting Options.Central Station Receiver 1 Format• From the table at the right enter the receiver format.• Press 0 through 9, and G0 for blank (ï).• Press G1 through G4 for letters BñE.• Press U to save and press the NEXT/YES button to proceed.DATAENTRYCS RECEIVER 1 FORMATblank(ï) Ademco Slow, Silent Knight Slow1 Sescoa, Vertex, DCI, FranklinFast2 Radionics Fast3 Silent Knight Fast4 Radionics, DCI, Franklin Slow5 Universal High Speed8 Radionics BFSKDATAENTRYCS RECEIVER 1 FORMAT9 FBI 4/3/10 Radionics Modem 2B SIAC Ademco Point IDD Ademco ExpressE PagerNOTE: Modem IIe is available only in DirectAddress Programming. Central StationReceiver 2 and 3 Formats can only be enteredin Direct Address Programming. See CSReceiver Options.(Direct Entry)25 INTERIOR BYPASS FIRE/TBL SYS TBL CHIMEINTERIOR BYPASS FIRE/TBL SYS TBL CHIME_ 3(Direct Entry)26 INTERIOR BYPASS FIRE/TBL SYS TBL CHIMEINTERIOR BYPASS FIRE/TBL SYS TBL CHIME8GEM-RP3DGTL/GEM-K3DGTL AND GEM-RP4RFC/GEM-K4RF KEYPAD EASY PROGRAM MENU(Direct Entry)24 INTERIOR BYPASS FIRE/TBL SYS TBL CHIMEINTERIOR BYPASS FIRE/TBL SYS TBL CHIME_ 3