X GEM-P9600 Programming Instructions L NAPCO Security Systems! Page 6 WI 1185 6/03GEM-RP2ASe2/GEM-K2AS Keypad Easy Program MenuEnter the Dealer Security Code (default = 456789) for a new panel or enter your custom Dealer Program Code ifprogrammed. Press the PRIOR/NO button repeatedly until ìTURNON/PROGî is displayed. NOTE: If you pass ìTURNON/PROGî, you can scroll back by pressing B. Press the NEXT/YES button to enter the Dealer Program Mode. Ineach of the following steps, press R to jump to the next screen, the NEXT/YES button to go forwards, thePRIOR/NO button to go backwards, U to save and C twice to exit at any time.Total Number of Zones in Area 1 (New Program Only)• Enter the total number of zones to be programmed for Area 1.• Valid entries are from 01 to 96. Directly enter the total number of zones, including leading zeros.• The system is based on groups of 4 zones each (after the first 8 zones), and will automatically round up to the nextgroup of 4. For example, if you enter 18, it will automatically convert this to 20 zones. Press U to save. Press theNEXT/YES button to proceed.Total Number of Zones in Area 2 (New Program Only)• Enter the total number of zones to be programmed for Area 2.• Valid entries are from 01 to 96. Directly enter the total number of zones, including leading zeros.• The system is based on groups of 4 zones each (after the first 8 zones), and will automatically round up to the nextgroup of 4. For example, if you enter 18, it will automatically convert this to 20 zones. Press U to save. Press theNEXT/YES button to proceed.Fire Zones in Area 1 (New Program Only)• Enter the zone number of any Fire Zones (including 2-wire, 4-wire or wireless).• Valid entries are from 01 to 96.• Directly enter each zone number, including leading zeros, and press U to save, and then repeat for any additionalzone(s). Press the NEXT/YES button to proceed.2-Wire Fire Zones in Area 1 (New Program Only)• Enter the zone number of any Fire Zone (from previous question) to be used with 2-wire smoke detectors.• Valid entries are 07 and 08. Directly enter each zone number, including leading zeros.• Press U to save, and repeat for any additional zone(s); press NEXT to proceed.NOTE: Only zones which have been designated as Fire Zones can be programmed as 2 Wire Fire zones. JP3 mustbe set to ì2-WFî position for 2-wire fire. (refer to Installation Instructions).Local or Central Station Reporting System (New Program Only)Press the NEXT/YES button for all zones to report; press the PRIOR/NO button for local system.Exit/Entry Zones in Area 1 (New Program Only)• Enter the zone numbers of zones to be used as Exit/Entry zones.• Valid entries are from 01 to 96. Directly enter each zone number, including leading zeros.• Press U to save and repeat for any additional zone(s); press the NEXT/YES button to proceed.NOTE: Exit/Entry Entry time of 30 seconds will automatically be programmed.Interior Zones in Area 1 (New Program Only)• Enter the zone numbers to be used as Interior Zones.• Valid entries are from 01 to 96. Directly enter each zone number, including leading zeros.• Press U to save and then repeat for any additional zone(s).• Press the NEXT/YES button to proceed.• All Interior zones will also be automatically programmed as ìExit/Entry Followerî and as "Power Up Delay" zones.RCOMPUTERIZED SECURITY SYSTEMARMEDSTATUSSYSTEM ARMED01/01/97 12:00AM1 2435 67 8 9 0ABCD EFGNEXT/YESPRIOR/NOAREAGEMINIENT A1ENT A1GEM-RP2ASE2/GEM-K2AS KEYPAD EASY PROGRAM MENU(Direct Entry)Ent A1#ZnXX(Direct Entry)Ent A2#ZnXX(Direct Entry)Ent FrZn#X X(Direct Entry)Ent2WFZn#X X(Press YES or NO)Reportall ZnY/N(Direct Entry)EntEE1Zn#X X(Direct Entry)EntFolZn#XX