4 - 128 S-100 • S-105 • S-120 • S-125 Part No. 102916June 2011Section 4 • Repair ProceduresREV A3 Tag, disconnect and plug the hydraulic hosesfrom the manifold that is mounted to the motor.Bodily injury hazard. Sprayinghydraulic oil can penetrate andburn skin. Loosen hydraulicconnections very slowly to allowthe oil pressure to dissipategradually. Do not allow oil to squirtor spray.4 Remove the motor/brake mounting fasteners.Remove the motor from the brake.a motorb motor/brake mounting boltsc braked drive hub mounting boltse drive hub12-1Turntable Rotation HydraulicMotor and Drive HubHow to Remove the TurntableRotation Hydraulic MotorNote: When removing a hose assembly or fitting,the O-ring on the fitting and/or hose end must bereplaced and then torqued to specification duringinstallation. Refer to Section Two,Hydraulic Hoseand Fitting Torque Specifications.1 Secure the turntable from rotating with theturntable rotation lock pin.2 Remove the ground controls side fixed turntablecover. See 5-1,How to Remove a FixedTurntable Cover.Turntable Rotation Componentsunlocked lockedbacde