Part No. 139378 Z-30/20N • Z-30/20N RJ • Z-34/22 • Z-34/22N 3 - 11Section 3 • Scheduled Maintenance ProceduresJune 2011REV B CHECKLIST B PROCEDURES9 Check the ambient air temperature and adjustthe specific gravity reading for each cell asfollows:• Add 0.004 to the reading of each cell forevery 10° / 5.5° C above 80° F / 26.7° C.• Subtract 0.004 from the reading of each cell forevery 10° / 5.5° C below 80° F / 26.7° C.Result: All battery cells display a specificgravity of 1.277 +/- 0.007. The battery is fullycharged. Proceed to step 10.Result: One or more battery cells display aspecific gravity from 1.269 to 1.218. The batteryis still usable, but at a lower performance so willneed to be recharged more often. Proceed tostep 11.Result: One or more battery cells display aspecific gravity from 1.217 to 1.173. The batteryis approaching the end of its life. Proceed tostep 11.Result: The difference in specific gravityreadings between cells is greater than 0.1 ORthe specific gravity of one or more cells is 1.172or less. Replace the battery.10 Check the battery acid level. If needed,replenish with distilled water to 1/ 8 inch / 3 mmbelow the bottom of the battery fill tube. Do notoverfill.11 Install the vent caps and neutralize anyelectrolyte that may have spilled.B-2Inspect the Electrical WiringNote: Genie specifications require that thisprocedure be performed every 250 hours orquarterly, whichever comes first.Maintaining electrical wiring in good condition isessential to safe operation and good machineperformance. Failure to find and replace burnt,chafed, corroded or pinched wires could result inunsafe operating conditions and may causecomponent damage.Electrocution/burn hazard. Contactwith hot or live circuits could resultin death or serious injury. Removeall rings, watches and otherjewelry.1 Remove the drive chassis cover from thenon-steer end of the machine.2 Inspect the following areas for burnt, chafed,corroded and loose wires:• Electrical power panel• Electrical relay panel• Ground control panel• Function manifold wiring