4-8Figure 4-8 Slot arrangement on the MSR 30-40(1) (2)(3)(7)(6)(8)(9)(4)(5)(1) Slot 0 (2) Slot 1 (3) Slot 2(4) Slot 3 (5) Slot 4 (6) Slot 5(7) Slot 6 (8) Slot 7 (9) Slot 8Figure 4-9 Slot arrangement on the MSR 30-60(1) (2)(3)(7)(6)(8)(10)(11) (9)(5) (4)(1) Slot 0 (2) Slot 1 (3) Slot 2(4) Slot 3 (5) Slot 4 (6) Slot 5(7) Slot 6 (8) Slot 7 (9) Slot 8(10) Slot 9 (11) Slot 10Interface numberingThe MSR 30 Series Router interface adopts “two dimension” numbering rules, shown in the following:z The interfaces are represented by interface-type X/Y, where interface-type can be serial,asynchronous, ethernet or ATM, and so on; X specifies the slot number; Y specifies the interfacenumber.z Different interfaces on an interface module share the same slot number X.z For every interface, Y starts from 0 and indicates the interface sequence on the interface module,from left to right.If you install a MIM-1FE and an MIM-2FE respectively in slot 5 and slot 6 on the MSR 30-20, theEthernet interfaces are numbered as follows:z Fixed Gigabit Ethernet interfaces are Gigabit Ethernet 0/0 and Gigabit Ethernet 0/1;z The Ethernet interface on the FIC-1FE is Ethernet 5/0;z The Ethernet interfaces on FIC-2FE are Ethernet 6/0 and Ethernet 6/1.