65System power-supply policy: enableSystem power-module redundant(configured): 1System power usable: 18000 WattsSystem power redundant(actual): 2000 WattsSystem power allocated: 2620 WattsSystem power available: 15380 WattsSYSTEM POWER USED(CURRENT): 470.00 WattsSystem power monitoring unit:Software version: 100Type In/Out Rated-Vol(V) Existing Usable Redundant(actual)---------- ------ ------------ -------- ------ -----------------PSE9000 AC/DC 220(default) 10 9 1DC output voltage information:Tray Value(V) Upper-Threshold(V) Lower-Threshold(V) Status---- -------- ------------------ ------------------ -------1 50.00 53.00 47.00 Normal2 50.00 53.00 47.00 NormalDC output current information:Total current(A): 2.00Branch Value(A)------ --------1 N/A2 0.903 1.404 0.805 1.506 0.407 0.908 0.609 0.9010 N/A11 1.0012 1.00PSU Status:ID Status Input-Err Output-Err High-Temperature Fan-Err Closed Current-Limit-- ------- ----------- ---------- ---------------- ------- ------ -------------1 Absent2 Normal3 Normal4 Normal5 Normal6 Normal7 Normal