46Fixed fan tray failureThe S5560X-34S-EI and S5560X-54S-EI switches each use a fixed fan tray. If the fan tray fails,contact H3C Support.Hot-swappable fan tray failureWARNING!• If both fan trays fail during switch operation, replace them within 2 minutes.• If one fan tray fails, perform either of the following tasks:{ If the ambient temperature is not higher than 27°C (80.6°F), replace the fan tray within 24 hours andmake sure the failed fan tray remains in position before the replacement.{ If the ambient temperature is higher than 27°C (80.6°F), replace the fan tray immediately.The S5560X-EI switches except the S5560X-34S-EI and S5560X-54S-EI use hot-swappable fantrays. If a fan tray fails, see "Installing/removing a fan tray" to replace the fan tray.Configuration terminal display problemsIf the configuration environment setup is correct, the configuration terminal displays bootinginformation when the switch is powered on. If the setup is incorrect, the configuration terminaldisplays nothing or garbled text.No displaySymptomThe PC displays nothing when the switch is powered on.SolutionTo resolve the problem:1. Verify that the power module is supplying power to the switch.2. Verify that the console cable is correctly connected.3. Verify that the console cable does not have any problems and the PC settings are correct.4. If the problem persists, contact H3C Support.Garbled displaySymptomThe display on the PC is garbled.SolutionTo resolve the problem:1. Verify that the following settings are configured for the terminal:{ Baud rate—9,600.{ Data bits—8.{ Stop bits—1.{ Parity—None.