21Field DescriptionBurst size Length of the packet or byte burst to consider for applying the meter.Byte count Number of bytes processed by a band.If the statistics cannot be collected, this field displays two hyphens (--).packet count Number of packets processed by a band.If the statistics cannot be collected, this field displays two hyphens (--).Referenced information Information about the meter entry used by flow entries.Count Total number of flow entries that use the meter entry.Flow table Flow table to which the flow entries that use the meter entry belong.Flow entry Flow entries that use the meter entry.display openflow summaryUse display openflow summary to display brief OpenFlow instance information.Syntaxdisplay openflow instance summaryViewsAny viewPredefined user rolesnetwork-adminnetwork-operatorExamples# Display brief OpenFlow instance information. display openflow summaryFail-open mode: Se - Secure mode, Sa - Standalone modeID Status Datapath-ID Channel Table-num Port-num Reactivate1 Active 0x0000000100001221 Connected 2 8 N10 Inactive - - - - -4094 Active 0x00000ffe00001221 Failed(Sa) 2 0 NTable 10 Command outputField DescriptionID OpenFlow instance ID.StatusActivation status of the OpenFlow instance:• Active—The OpenFlow instance has been activated.• Inactive—The OpenFlow instance has not been activated.Datapath-ID Datapath ID of the OpenFlow instance.If the OpenFlow instance is not activated, this field displays a hyphen (-).ChannelStatus of the OpenFlow channel to the controller:• Connected—An OpenFlow channel has been established.• Failed(Se)—The OpenFlow channel is disconnected from the controller,