Installation ManualH3C S7502 Ethernet Switch Chapter 5 System Commissioning5-6Caution:Before powering on the switch, confirm where the power switch of the equipment roomis located, so that you will be able to power off in case of accidence.5.2.2 Power-onz Turn on the power supply of the switch.z Power on the switch.5.2.3 Check after Power-on (Recommended)You are recommended to check as follows after powering on the switch to ensure theconfigurations thereafter.z After a switch is powered on, the heat dissipation system starts working. You canhear the noise as the fan rotates and feel air flow out from the vent.z Check if any system indicator on the SRPU indicates abnormal condition.5.2.4 Starting the InterfaceAs the switch is started, the configuration terminal will yield the following output:Starting......RAM Line....OKSystem is booting................******************************************* ** H3C S7502 BOOTROM, Version 530 ** *******************************************Copyright(c) 2004-2007 Hangzhou H3C Tech. Co., Ltd.Creation date : Apr 20 2007, 14:48:52CPU type : MPC8245CPU Clock Speed : 300MhzBUS Clock Speed : 33MhzBOOT_FLASH type : M29W040BFlash Size : 32MBMemory Size : 256MBS7502 main board self testing................................SDRAM Data lines Selftest.................................OK!SDRAM Address lines Selftest..............................OK!