When the mounting plate is firstly fixed1. Carry out, based on the neighboring pillars or lintels, a proper leveling for the plateto be fixed against the wall, then temporarily fasten the plate with one steel nail.2. Make sure once more the proper level of the plate, by hanging a thread with aweight from the central top of the plate, then fasten securely the plate with theattachment steel nail.3. Making a Hole on the wall and Fitting the piping Hole coverMake a hole of 60mm in diameter,slightly descending to outside the wall.Install piping hole cover and seal itoff with putty after installation.4. Drawing of pipeRear pipingDraw pipes and the drain hose, then fasten them with the adhesive tape.Left Left-rear, pipingIn case of left side piping, cut away, with a nipper, the lid for left piping.In case of left-rear piping, bend the pipes according to the piping direction to the markof hole for left-rear piping which is marked on heat insulation materials.a. Insert the drain hose into the dent of heat insulation materials of indoor unit.b. Insert the indoor/outdoor electric cord from backside of indoor unit, and pull it outon the front side, then connect them.c. Coat the flaring seal face with refrigerant oil and connect pipes.Cover the connection part with heat insulation materials closely, and make sure fixingwith adhesive tape.Indoor/outdoor electric cord and drain hose must be bound with refrigerant piping byProtecting tape.Indoor side Outdoor sideWall hole Thicknessof wall60mm(Section of wall hole) Piping hole pipeIndoor/OutdoorElectric cablePipe supportingplateHeat insulationmaterialDrain hoseLid for left pipingLid for right pipingLid for under piping pipeFix with adhesive tapePiping -91-