Drawing for the installation of indoor and outdoor unitsNecessary Tools for InstallationHammerƽ Torque wrenchƽ(17mm,22mm,26mm)NipperƽReamerƽHacksawƽ Pipe cutterƽGas leakage detector orƽsoap-and-water solutionHole core drillƽ Flaring toolƽSpanner(17,19 and 26mm)ƽ KnifeƽMeasuring tapeƽƽƽƽƽƽPlace where the distance of more than lm from televisions, radios, wireless apparatusesand fluorescent lamps can be left.ƽIn the case of fixing the remote controller on a wall, place where the indoor unit canreceive signals when the fluorescentƽ lamps in the room are lightened.ƽƽPlace, where discharged wind and noise do not cause a nuisance to the neighbors.ƽPlace, where a distance markedƽ is available as illustrated in the above figure.Before inserting power plug into receptacle, check the voltage without fail.The power source is the same as theƽ corresponding name plate.Install an exclusive branch circuit of the power.ƽA receptacle shall be set up in a distance where the power cable can bereached.Do not extend the cable by cutting it.ƽSelection of Installation PlacePower SourcePreparationNO.0010519373Installation Manual of Room Air ConditionerFACEDOptional parts for pipingNon-adhesive tapeAdhesive tapeSaddle (L.S) with screwsConnecting electric cablefor indoor and outdoorDrain hoseHeating insulating materialPiping hole coverFloor fixing dimensions of theoutdoor unit (Unit:mm)Fixing of outdoor unitFix the unit to concrete or blockƽwith bolts (10mm) and nuts firmlyand horizontally.When fitting the unit to wallƽsurface, roof or rooftop, fixa supporter securely with nailsor wires in consideration ofearthquake and strong wind.If vibration may affect theƽhouse, fix the unit by attaching avibration-proof mat.The marks from toin the figure are theparts numbers.The distance betweenthe indoor unit and thefloor should be morethan 2m.The models adopt HCFC free refrigerant R410Amore than 10cmmore than 5cmmore than 10cmmore than 10cmmore than10cmmore than15cmmore than 60cmAGƽƽAFCEDGBArrangement of pipingdirectionsRear leftLeft RearrightRightBelowGAttention must be paid tothe rising up of drain hoseIndoor Unit - Select a plocation that isOutdoor Unit - Select a plocation that isRobust not causing vibration, where the body can be supported sufficiently.Not affected by heat or steam generated in the vicinity, where inlet and outlet of theunit are not disturbed.Possible to drain easily, where piping can be connected with the outdoor unit.Where cold air can be spread in a room evenly.Nearby a power receptacle. (Refer to drawings).Not less affected by rain or direct sunlight and is sufficiently ventilated.Strong enough to bear the unit, where vibration and noise are not increased.113.5 633 113.5043Read this manual before installationExplain sufficiently the operating means to the user according to this manual.Please be subject to the actual product purchased , the above picture is just for your reference.184 580 184083For 24KFor 18K