must be filed promptly; otherwise, the carrier may not acceptthe claim.2.4.3 Factory Test Data SheetsFactory test data is supplied with each transmitter. It lists pa-rameters for operation of the transmitter. These readings wererecorded during factory testing. Locate the test data and place itin the manual at the end of the maintenance section.Record the same readings periodically to establish and maintainan information base from which to work in the event of futurechanges or problems.FACTORY TEST DATA LOCATED2.4.4 Cabinet Placement and LevelingFour bolts hold the cabinet to its skid. They are located two perside, front and rear. When the cabinet is in its final position, youmay need to level the cabinet. The HT EL cabinet has levelingjacks in the corners to aid in leveling the cabinet on un-evenfloors. The four 0.5 inch hold-downs in the bottom of the cabinetused to bolt the cabinet to the shipping skid that may be used tobolt the unit to the floor. Level the cabinet using shims under thebottom, this is important to avoid deforming the cabinet whenbolting it to the floor.Install the power module assembly in the bottom of the rack. Itwill slide into mating electrical connectors. Install the Exciter(s)and connect power and signal cables to exciter(s).NOTEDO NOT INSTALL RF MODULES AT THIS TIMEFigure 2-1. Transformer TapsSection II - Installation888-2457-001 2-3WARNING: Disconnect primary power prior to servicing.