12/20/11 888-2595-001 A-17WARNING: Disconnect primary power prior to servicing.Appendix A - FM Web Remote OptionZX SeriesA.5.2 Perform Simple ResetPurpose: Issues simple reset of microprocessor. Essentially the same as cycling powerto card.Special Tools: Small plastic screwdriver.STEP 1 Locate WEB RESET hole on I/O panel at upper rear face of amplifierchassis. (See Figure A.6)STEP 2 Press button continually with small plastic adjustment tool or similaritem for ten seconds. Maintain button depressed continually for full tenseconds.STEP 3 Web remote processor resets and will resume operation within secondsof button release.STEP 4 Procedure complete.WRITECOMMUNITY The SNMP WRITE community for SET commands.VALID SET VALUE As an added security measure, the value “written” by the SNMP SET must matchthis value. Otherwise, no command will be issued.SNMP TRAPENABLEDEnables alarm notification of an RF < ALARM THRESHOLD fault via a genericSNMP trap. Toggling this setting from 0(off) to 1(on) will cause a test trap to besent.SNMP TRAPADDRESSThe destination IP address of the trap notification.VERSION The software version of the web remote.Table A-3 List of settings on configuration page.