Diagnostic Error Code FRU/Action175-199-XXXThermal Sensor(s) test failed, causeunknown1. Go to the ″Undetermined problems″section2. Flash the system and re-test3. Replace component under function test175-250-XXX175-251-XXXThermal Sensor(s) limit error1. Check fans2. Check Power supply3. Microprocessor4. System board185-000-XXXAsset Security Test Passed 1. No action185-XXX-XXXAsset Security failure 1. Flash system2. System board185-278-XXXAsset Security Chassis Intrusion 1. Assure Asset Security Enabled2. C2 Cover Switch3. System board201-000-XXXSystem Memory Test Passed 1. No action201-XXX-XXXSystem Memory error 1. Replace the memory module called outby the test2. System board202-000-XXXSystem Cache Test Passed 1. No action202-XXX-XXXSystem Cache error 1. Cache, if removable2. System board3. Microprocessor206-000-XXXDiskette Drive Test Passed 1. No action206-XXX-XXXDiskette Drive error 1. Diskette Drive Cable2. Check power supply voltages3. Diskette drive4. System board215-000-XXXCD-ROM Drive Test Passed 1. No action215-XXX-XXXCD-ROM Drive error 1. CD-ROM Drive Cable2. Check power supply voltages3. CD-ROM drive4. System board217-000-XXXHard Disk Drive Test Passed 1. No action217-25X-XXX217-26X-XXXHard Disk Drive (IDE) error1. Hard Disk Drive Cable2. Check power supply voltages3. Hard Disk drive (IDE)4. System boardChapter 5. Symptom-to-FRU Index 53