Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item9239 Frame Node FaultAn internal error in the SPCN frame node prevents the running of a Framecommand.TWRCARDAJDG301923A ASA FailureThe frame address returned by a secondary node does not match theaddress of the frame.TWRCARDAJDG301923B Invalid Packet Length for data sent.An Invalid Packet Length occurred for data exchanged.AJDG301TWRCARD9280 Response Stack OverflowToo many responses were received during System Frame commandprocessing.CBLALLAJDG301TWRCARD9281 Response OverrunResponse Overrun occurred during System Frame processing.CBLALLAJDG301TWRCARD9282 No Free EntriesNo free entries were found during System Frame processing.CBLALLAJDG301TWRCARD9283 ARA FailureAn Assign Frame Address Failure occurred during ARA Preprocessing.TWRCARDAJDG3019284 Undefined statusUndefined Status occurred during Frame or STF processing.TWRCARDAJDG3019285 BCC FaultA BCC Error was detected during Network post processing.TWRCARD9286 Length Check Error.Length Check occurred during SPCN post processing.TWRCARDAJDG3019287 Undefined statusUndefined Status occurred during Command processing.TWRCARDAJDG3019288 Configuration ErrorA configuration error was detected during System Frame processing.TWRCARDAJDG3019289 Invalid Packet Length for data sent.Invalid Packet Length occurred for data exchanged.AJDG301TWRCARDA100 Battery Power Unit capacity test failureThe battery power unit capacity test time exceeds the installed batterycapacity. The battery power may not be enough to provide a controlledstop during a loss of incoming ac voltage.This reference code is logged for information only.A201 A Battery Power Unit 1 FailedBattery power unit 1 capacity test failed.BATRYBATCHGRA202 Battery Power Unit 2 FailedBattery power unit 2 capacity test failed.BATRYBATCHGR1xxx116 iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System ReferenceCodes)