HDC-UHD Series User Guide639.4.14 Copying EDID’s CEC physical addressYou can copy CEC physical address of the sink device that is connected to OUT1 to the HDC EDID. CECpasses through between IN1 and OUT1.Menu F38: IN1WEB menu EDID SETTINGS → CEC ADDRESS COPYSetting value[Table 9.24] CEC physical addressSetting Front WEB browserNot copying physical address [Default] oFF OFFCopying physical address on OUT1The setting will be applied only if CEC-supported source device and sink device is connected and“9.4.2 Resolution” is set to one of “03” to “46”.If the CEC physical address of the connected sink device and HDC’s address are not the same, the CECfunctions, such as input switching in the sink device at start-up, may not work correctly. The problem can besolved by using the CEC physical address that is copied in the HDC.Note:CEC system link functions supported by other manufacturers’ are not guaranteed to work correctly by thissetting. Check the actual configuration.9.4.15 Input video frequencyFor 2160p and 4096x2160 EDID resolutions, the frequency will be 30 Hz or 25 Hz.Menu F40 to F41: IN1 to IN2WEB menu EDID SETTINGS → FRAME RATESetting value[Table 9.25] Input video frequencySetting Front WEB browserOFF [Default] oFF 60Hz/30HzON on 50Hz/25HzThe setting will be applied only if “9.4.2 Resolution” is set to one of “03” to “46”.