24IDS 1632 User Manual 700-256-01I Issued March 2009Table 3 : Trouble ConditionsIndicator Trouble Condition1 AC Mains Failure2 Failure to communicate successfully to monitoring company3 Phone line trouble4 Siren tamper5 Low battery6 Loss of Clock Timer7 Engineer Reset8 Box tamper9 n/a10 Tamper on peripheral device11 Communication loss to peripheral device12 Loss of power to peripheral devices13 Reserved14 SIM PIN Trouble15 Low Airtime19. Changing a PartitionHold down the [MODE] key until the beep,then enter [1] [*] [Partition Number] [*]To change partitions the keypad must be a global keypad.1. Ensure that the Panel is disarmed2. Hold [MODE] until the keypad beeps.3. Press [1] [*] followed by the [Partition Number] [*].If no key is pressed on the keypad for specified delay period (default is 20 seconds), the keypad willbeep and default back to its original partition. The keypads may be programmed to remain in the newpartition. (Ask your Installer about this option). Entering partition numbers other than those in the range 1to 8 will produce a key entry error.20. Output Control via a KeypadIf the panel has been set up to control switching functions via its outputs, these can be controlled via thekeypad - e.g. turning lights on and off.Hold down the [MODE] key and press [3] [*].(Any outputs that are currently set [ON] will be shown as an on zone indicator.)To toggle the output status, enter [OUTPUT NUMBER] followed by [*]. Press [#] to exit User ProgramMode.Ensure that you have checked with your installer which outputs are used for radio reporting soas to prevent the triggering of false alarms.