12 AfiMilk MPC Installation ManualTo adjust the G parameter valua follow the procedure in paragraph Adjusting G and/or Hparameter value or via the AfiControl interface mentioned in paragraph Adjusting the Gand/or H parameter value via communication.7.3.1.1 Equipment and water test preparation and description7.3.1.1.1 Equipment requiredFor performing the AfiMilk MPC water test, the followingequipment is used:Milking bucket equipped with 7/8” inlet and vacuum portsManual vacuum shut off valve placed between the milk lineand the hose connected to the collection bucket.Suction pipe with an inlet hole of 3.5mm, which allows a 4 ± 1 LPM (Liter per Minute)flow of water. The entire set should betested and verified for the defined flowrate (see testing the equipmentbelow). This part will replace themilking claw for the purpose of thetest.Make sure you work accurate with collecting all the data you need.This includes i.e. missing data due to missing cow identification, milk thruthe meter but not in the bulk tank and milk substraction out of bulk tank..IMPORTANT