Icar RPC 8BGA Instruction Manual
Also see for RPC 8BGA: Quick guideComplete manualOperating manualResetting guide
p. 11 / 39User Alarms (UAx) The user has the possibility to define a maximum of 8 programmablealarms (UA1…UA8). For each alarm, it is possible to define:o the source that is the condition that generates the alarm,o the text of the message that must appear on the screen when thiscondition is met.o The properties of the alarm (just like for standard alarms), that is inwhich way that alarms interacts with the power factor correction. The condition that generates the alarm can be, for instance, theovercoming of a threshold. In this case, the source will be one of the limitthresholds LIMx. If instead, the alarm must be displayed depending on the status of anexternal digital input, then the source will be an INPx. For every alarm, the user can define a free message that will appear on thealarm page. The properties of the user alarms can be defined in the same way as thenormal alarms. You can choose whether a certain alarm will disconnect thesteps, close the global alarm output, etc. See chapter Alarm properties. When several alarms are active at the same time, they are displayedsequentially, and their total number is shown on the status bar. To reset one alarm that has been programmed with latch, use thededicated command in the commands menu. For details on alarm programming and definition, refer to setup menuM26Ошибка! Источник ссылки не найден.Пользовательские аварийные сигналы (UAx) Пользователь может определить не более 8 программируемых аварийныхсигналов (UA1…UA8). Для каждого аварийного сигнала можно определить:o источник, являющийся условием создания аварийного сигнала,o текст сообщения, появляющегося на экране при выполненииусловия,o свойства аварийного сигнала (подобные стандартным аварийнымсигналам), то есть то, как аварийные сигналы воздействуют накоррекцию коэффициента мощности. Например, условием, создающим аварийный сигнал, является превышениепорога. В этом случае источником будет один из пороговых пределов LIMx. Если, наоборот, в зависимости от состояния внешнего цифрового входа,требуется отобразить аварийный сигнал, то источником будет INPx. Для каждого аварийного сигнала пользователь может определитьпроизвольное сообщение, которое будет показано на странице аварийныхсигналов. Свойства пользовательских аварийных сигналов можно определить такимже образом, как свойства обычных сигналов. Можно задать отключениеступеней по определенным сигналам, глобальное закрытие выходов, и такдалее. См. раздел «Свойства аварийных сигналов». При активации нескольких аварийных сигналов одновременно ониотображаются последовательно, и общее количество показывается встроке состояния. Чтобы сбросить один аварийный сигнал с запрограммированнойфиксацией, в меню команд имеется специальная команда. Подробную информацию о программировании и определении аварийныхсигналов см. в меню настройки M26Ошибка! Источник ссылки не найден.Master-Slave configuration To further extend the flexibility of use of DCRG8 it is available the Master-Slave function, which allows, for plants with high installed power, tocompose a series of panels in cascade, each with its own controller andassociated capacitor banks. This solution allows to expand in a modular way the power factor correctionsystem, in case it becomes necessary because of the increased needs ofthe plant. In this configuration, measurements are made only from the first controller(Master) which controls a maximum of 32 logical steps, that are then sentto all the slave units. The slave controllers drive their steps as indicated by the master, whileperforming the ‘local’ protections like panel or capacitor overtemperature,no-voltage release, harmonic protections etc. The maximum possible configuration is one master with 8 slaves.Example 1 (application in series):It is required to create a system with 18 step of 40kvar each, divided intothree identical panels with 6 step (240kvar) each. For each panel, the 8 relayoutputs of the controller are used as follows: the first six for the steps (OUT1..6), the seventh for the cooling fan (OUT7) and the last for the alarm (OUT8).On the master panel we will define 18 logical step of 50kvar. The steps from 1to 6 will be 'mapped' on the outputs OUT1 .. 6 of the master, those from 7 to12 on the outputs OUT1 .. 6 of slave1 and finally the steps from 13 to 18 onthe outputs OUT1 .. 6 of the slave 2. In this case, the parameter P02.07Smallest step power will have to be set (on the master) to 40kvar.Programming of the master:PARAMETER VALUE DESCRIPTIONP02.07 40 40 kvarP03.01.01…P03.18.01 1 All the 18 logic steps are 40kvarP04.01.01…P04.06.01 Step 1…6 Outputs OUT1…OUT6 of the master are activatedby logical steps 1…6.P04.07101 Fan OUT7 of the master controls cooling fanP04.08.01 All glb 1 OUT8 of the master controls global alarm 1P05.01 COM1 COM port used for the linkP05.02 Master Role of masterP05.03…P05.04 ON Enables slave 1 and slave 2P06.01.01…P06.06.01 Step 7…12 Outputs OUT1…OUT6 of slave 1 are activated bylogical steps 7…12.P06.07.01 Fan OUT7 of slave 1 controls cooling fanP06.08.01 All glb 1 OUT8 of slave 1 controls global alarm 1P07.01.01…P07.06.01 Step 13…18 Outputs OUT1…OUT6 of slave 2 are activated bylogical steps 13…18.P07.07.01 Fan OUT7 of slave 2 controls cooling fanP07.08.01 All glb 1 OUT8 of slave 2 controls global alarm 1Programming of slave 1:P05.02 Slave1 Role: slave1Конфигурация «Ведущее-подчиненное устройство» Для обеспечения дополнительной универсальности DCRG8, доступнафункция «ведущее-подчиненное устройство». Благодаря ей на объектах свысокой установленной мощностью можно объединять несколько приборовв каскад, каждый со своим собственным регулятором и связаннымибатареями конденсаторов. Это решение позволяет добиться модульного расширения системыкорректировки коэффициента мощности по мере увеличения потребностейустановки. В такой конфигурации измерения выполняет только первый регулятор(ведущий), управляющий максимально 32 логическими ступенями, которыезатем передаются всем подчиненным устройствам. Ступени на подчиненных устройствах задаются ведущим прибором. Приэтом подчиненные устройства обеспечивают «местную» защиту, напримерот перегрева панели или конденсатора, от отсутствия напряжения,гармонических искажений и т.д. В максимально возможной конфигурации присутствует одно ведущееустройство и 8 подчиненных.Пример 1 (последовательное применение):Необходимо создать систему с 18 ступенями по 40 квар каждая, сразделением на три идентичные панели по 6 ступеней (240 квар). Длякаждой панели 8 релейных выходов используются следующим образом:первые шесть для ступеней (OUT1. .6), седьмой для вентилятораохлаждения (OUT7) и последний для аварийного сигнала (OUT8). На ведущейпанели задается 18 логических ступеней по 50 квар. Ступени с 1 по 6назначаются выходам OUT1 .. 6 ведущего устройства, ступени с 7 по 12 –выходам OUT1 .. 6 подчиненного устройства 1 и, наконец, ступени с 13 по18 присваиваются выходам OUT1 .. 6 подчиненного устройства 2. В этомслучае параметру P02.07 Smallest step power (Наименьшая мощностьступени) необходимо будет присвоить значение 40 квар (на ведущемустройстве).Программирование ведущего устройства:ПАРАМЕТР ЗНАЧЕНИЕ ОПИСАНИЕP02.07 40 40 кварP03.01.01…P03.18.01 1 Все 18 логических ступеней по 40 кварP04.01.01…P04.06.01 Step 1…6 Выходы OUT1…OUT6 ведущего устройстваактивируются логическими ступенями 1…6.P04.07101 Вентилятор OUT7 ведущего устройства управляетвентилятором охлажденияP04.08.01 All glb 1 OUT8 ведущего устройства управляетглобальным аварийным сигналом 1P05.01 COM1 COM-порт, используемый для связиP05.02 Master Роль ведущего устройстваP05.03…P05.04 ON Включение подчиненного устройства 1 иподчиненного устройства 2P06.01.01…P06.06.01 Step 7…12 Выходы OUT1…OUT6 подчиненногоустройства 1 активируются логическимиступенями 7…12.P06.07.01 Fan OUT7 подчиненного устройства 1 управляетвентилятором охлажденияP06.08.01 All glb 1 OUT8 подчиненного устройства 1 управляетЧП «Профиэлектро»Т. +380 44 361-62-55, 80e-mail: info@profielectro.net.uawww. profielectro.net.ua |
Related manuals for Icar RPC 8BGA
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine