p. 9 / 39MODULE TYPE CODE FUNCTION MAX Nr.ADDITIONAL STEPS EXP 10 06 2 RELAY STEPS 4EXP 10 01 4 STATIC STEPS(FAST) 2COMMUNICATION EXP 10 10 USB 2EXP 10 11 RS-232 2EXP 10 12 RS-485 2EXP 10 13 Ethernet 1EXP 10 14 Profibus® DP 1EXP10 15 GSM-GPRS 1DIGITAL I/O EXP 10 00 4 INPUTS 2EXP 10 02 2 INPUTS +2 ST. OUTPUTS 4EXP 10 03 2 C/ORELAYS 4ANALOG I/O EXP 10 04 2 ANALOGINPUTS 2EXP 10 05 2 ANALOGOUTPUTS 2EXP 10 16CAPACITORHARMONICPROTECTION4ТИП МОДУЛЯ КОД ФУНКЦИЯ МАКС.КОЛ-ВОДОПОЛНИТЕЛЬНЫЕСТУПЕНИ EXP 10 062 РЕЛЕЙНЫХСТУПЕНИ 4EXP 10 014 СТАТИЧЕСКИХСТУПЕНИ(БЫСТРО)2МОДУЛЬ СВЯЗИ EXP 10 10 USB 2EXP 10 11 RS-232 2EXP 10 12 RS-485 2EXP 10 13 Ethernet 1EXP 10 14 Profibus® DP 1EXP10 15 GSM-GPRS 1ЦИФРОВЫЕ ВХОДЫ-ВЫХОДЫEXP 10 00 4 ВХОДА 2EXP 10 022 ВХОДА +2 ВЫХОДАСТУПЕНИ4EXP 10 032ПЕРЕКЛЮЧАЮЩИХРЕЛЕ4АНАЛОГОВЫЕВХОДЫ-ВЫХОДЫ EXP 10 04 2 АНАЛОГОВЫХВХОДА 2EXP 10 05 2 АНАЛОГОВЫХВЫХОДА 2EXP 10 16ЗАЩИТАКОНДЕНСАТОРАОТГАРМОНИЧЕСКИХИСКАЖЕНИЙ4Communication channels The DCRG8 supports a maximum of 2 communication modules, indicatedas COMn. The communication setup menu is thus divided into two sections(n=1 … 2) of parameters for the setting of the ports. The communication channels are completely independent, both for thehardware (physical interface) and for the communication protocol. The two channels can communicate at the same time. Activating the Gateway function it is possible to use a DCRG8 with both anEthernet port and a RS485 port, that acts as a bridge over other DCRGsequipped with RS-485 only, in order to achieve a more economicconfiguration (only one Ethernet port). In this network, the DCRG with Ethernet port will be set with bothcommunication channels (two among COM1, COM2 and and COM3) withGateway function set to ON, while the other DCRGs will be configurednormally with Gateway = OFF.Каналы связи Устройство DCRG8 поддерживает не более 2 модулей связи, обозначенныхкак COMn. Следовательно, меню настройки связи разделено на две группы(n=1 … 2) параметров настройки портов. Каналы связи полностью независимы, как аппаратно (физическийинтерфейс), так и по протоколу связи. Обмен данными возможен по двум каналам параллельно. При активации режима Gateway (Шлюз), устройство DCRG8 можноиспользовать с портом Ethernet и портом RS485 в качестве моста длядругих устройств DCRG, оснащенных только портом RS-485. Такой режимпозволит добиться более экономичной конфигурации (только один портEthernet). В сети такого типа на устройстве DCRG с портом Ethernet настраиваютсяоба канала связи (два из COM1, COM2 и COM3) с включенной функциейGateway, а на других устройствах DCRG функция Gateway обычноотключена.Inputs, outputs, internal variables, counters, analog inputs The inputs and outputs are identified by a code and a sequence number.For instance, the digital inputs are identified by code INPx, where x is thenumber of the input. In the same way, digital outputs are identified by codeOUTx. The sequence number of I/Os is simply based on their mounting position,with a progressive numbering from left to right. It is possible to manage up to 8 analog inputs (AINx), connected to externalanalog sensors (temperature, pressure, flow etc). The value read from thesensors can be scaled to any unit of measure, visualized on the displayand transmitted on the communication bus. The value read from analoginputs is shown on the dedicated display page. They can be used to driveLIMx limit thresholds, that can be linked to an internal or external output. The expansion I/O numbering starts from the last I/O installed on the baseunit. For example, with OUT1…OUT8 digital outputs on the base unit, thefirst digital output on the expansion modules will be OUT9. See thefollowing table for the I/O numbering:COD DESCRIZIONE BASE EXPINPx Digital Inputs - 1…8OUTx Digital Outputs 1…8 9…16COMx Communication ports - 1…2AINx Analog Inputs - 1…4AOUx Analog Outputs - 1…4 In a similar way, there are some internal bit-variables (markers) that can beassociated to the outputs or combined between them. For instance, it ispossible to apply some limit thresholds to the measurements done by thesystem (voltage, current, power, etc.). In this case, an internal variableВходы, выходы, внутренние переменные, счетчики, аналоговые входы Входы и выходы обозначаются кодом и порядковым номером. Например,цифровые входы обозначаются кодом INPx, где x – номер входа.Аналогичным образом, цифровые выходы имеют обозначение OUTx. Порядковый номер входов-выходов просто означает их положениеустановки с нумерацией слева направо. В общем, можно управлять 8 аналоговыми входами (AINx), подключеннымик внешним аналоговым датчикам (температуры, давления, расхода и т.д.).Значение измерения, получаемое от датчиков, может быть выраженолюбой единицей измерения, показано на дисплее и передано на шинусвязи. Значение, считываемое с аналоговых входов, выводится наотдельной странице экрана. Для значений можно задать пороговыепределы LIMx, которые можно коммутировать на внешний или внутреннийвыход. Нумерация входов-выходов модулей расширения начинается с последнеговхода-выхода, заданного на основном устройстве. Например, при наличиицифровых выходов OUT1…OUT8 на основном устройстве, первымцифровым выходом модуля расширения будет OUT9. Нумерация входов-выходов представлена в следующей таблице:КОД ОПИСАНИЕ БАЗА EXPINPx Цифровые входы - 1…8OUTx Цифровые выходы 1…8 9…16COMx Порты связи - 1…2AINx Аналоговые входы - 1…4AOUx Аналоговые выходы - 1…4 Подобным образом, имеются некоторые внутренние битовые переменные(маркеры), которые можно связать с выходами или объединить друг сдругом. Например, к измерениям, выполняемым системой (напряжение,сила тока, мощность и т.д.), можно применить некоторые пороговыепределы. В этом случае каждый раз, когда измерение будет выходить заЧП «Профиэлектро»Т. +380 44 361-62-55, 80e-mail: info@profielectro.net.uawww. profielectro.net.ua |
Related manuals for Icar RPC 8BGA
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine