42 SHORT LIST OF PARTS41 FAULT FINDING - CAUSES (CONT)BIM is defective or not properly connected, when started, the fan will rotate for a moment and then stops.Gas pressure detector (if present) is defective or the wires have not been properly connected.BIM is defective or not properly connected (contact Ideal Care Technical helpline).Check the electrical connections of the gas valve.Check the ModuLine room thermostat. If the thermostat functions properly, the control panel is defective.Replace the control panel.Check the mains supply.Replace the control panel if the malfunction remains after a reset or if the malfunction has occurred before at thiscontrol panel.The hot water tank is too small for this unit power (external hot water tank).The flow limiter is not properly adjusted.Electrical connection in cable loom (red / red-brown) disconnected. Flue gas thermostat (option) is activated oris defective.CauseNo.Cause description35363738394041424344Malfunction causes and remediesThe table shown below gives the possible cause of the malfunction described in frame 40.The table also provides instructions of how to remedy the malfunction.The following are parts commonly required as replacements,due to damage or expendability. Their failure or absence islikely to affect the safety and/or performance of thisappliance.The full list is held by Caradon Ideal distributors andmerchants.When ordering spares please quote:1. Boiler model.2. Description3. Quantity.FAULT FINDINGMaximiser SE - Installation 34Key No.7613454189727352-5650-991043536253928-3063-105G.C. No.E58-940E58-942E58-941E58-954E58-952E58-956E58-962E58-993E58-998E59-737E59-000E59-705E59-005E59-008E59-215E59-010E59-016E59-018E59-020E59-021E59-033E59-041E59-195E59-044E59-058E59-722E59-012DescriptionCasing doorCasing displayCasingCasing clamp left sideCasing clamp right sideCasing sealSyphon incl. seal 075604Pump UP 25-55 incl. 2x gasket 075552Gas valve incl. 2x conn. nipple 075579, 2x o-ring 075553 (SE42)Gas valve incl. 2x conn. nipple 075579, 2x o-ring 075553 (SE65)Burner Plaque Assembly (SE42)Burner Plaque Assembly (SE65)Burner thermostat 107˚CBurner sealing gasket (SE42)Burner sealing gasket (SE65)Control panel excluding on/off switchTemperature/pressure guage + capillary RD52IgniterIonisation ElectrodeSensor NTC 10 kΩ incl. o-ring 075363Safety sensor NTC 10 kΩ incl. o-ring 075363Lower Access Cover Seal (SE 42)Lower Access Cover Seal (SE 65)Mounting clip, lower access cover/burner housingFan (SE 42)Fan (SE 65)Mains switchQuantity111221111111111111112111111Product No.075626075628075627075606075600075607075574075620075580075718075571075720075618075610075721075561075623075558075559075560075586075608075730075616075585170838075631