Technical descriptionItem no. 10302204, Revision 00 11 ( 40 )5 Technical description5.1 Connections of HF spindle7 4 1 31 Electrical connection3 Sealing air G 1/8"4 Blow air through collet during tool change G 1/8"7 Pneumatic system for tool change G 1/8"5.2 Electrical connectionThe HF spindle may only be operated with a frequency converter (FC).Ü Check whether the current, voltage, and frequency data of the HF spindlematch the raw data for the frequency converter.Ü Use a motor supply line that is as short as possible.Ü Adjust the speed of the HF spindle using the FC.Ü Refer to the frequency converter manual for further information.The FC detects the following operating states of the HF spindle, depending onthe version:q HF spindle rotating.q HF spindle too hot.q HF spindle at a standstill, etc.The FC forwards the operating states of the HF spindle to the machine con-troller.Note: Connect the SpeedTEC quick locking connector.u For the combination SpeedTEC connector plug/SpeedTEC cable plug:u Remove the O ring on the SpeedTEC connector plug.