BM-500GE / BB-500GE216.5.2 Internal Trigger GeneratorExample: Create a trigger signal and trigger the cameraFeature Valuec)Acquisition andTrigger controlsTrigger selector Trigger Mode ONPulse Generators Pulse GeneratorselectorPulse Generator 0SelectorClock Choice 1 = Pixel Clock (30MHz)Counter Dividing Value 2960(line rate)Length Counter 0 1000 ClocksStart point Counter 0 100 ClocksRepeat Count 0 0End point Counter 0 500 ClocksClear activation OffTrigger source pulse generator 0Fig.14. Pulse Generator 0 timing Example 2LUT( Cross Point Switch )Pulse Generator 1(19 bit Counter )Pulse Generator 0(19 bit Counter )12 bitCounterCamera TRIGGER 0Camera TRIGGER 1GPIO Port 1(TTL OUT 1)GPIO Port 2(TTL OUT 2)GPIO Port 3(OPT OUT 1)GPIO Port 4(OPT OUT 2)Time Stamp ResetSequence ResetLVAL INDVAL INFVAL INEEN INGPIO Port In1(OPT IN 1)GPIO Port IN2(OPT IN 2)GPIO Port IN3(TTL IN )GPIO Port IN4(LVDS IN)Soft Trigger 0Soft Trigger 1Soft Trigger 2Soft Trigger 3INOUTPulse Generator 0Pulse Generator 1Pulse Generator 0Pulse Generator 1Digital I/O(GPIO) setting01234567121314151617Digital I/O(GPIO) setting01456716171213Setting forLine SourceSetting forLine SelectorPixel ClockCounter Clock Source1Counter Divide by value1/2 to 1/4096Bypass01 - 4095Pulse Generator Setting 0Start Point Counter 0Length counter 0Repeat Counter 0End point counter 0Counter 0 clearPulse Generator Setting 1①②⇒ 1000 clk⇒⇒⇒⇒100 clk0500 clk0 Free runPulse Generator 0100 Line500 Line1000 LineoutputPulse Generator 0100 Line500 Line1000 Lineoutput