— 37 —SP-12000M-CXP4 / SP-12000C-CXP4Bayer colorX89.12X16X7.15X5.62X1X0.451600037876 (X5.62)0 (X1)–4533 (X0.45)R&BRed Blue39dB-7dB0dB24dB15dB0dB–7dB15dB0dB–7dB15dB 37876 (X5.62)0 (X1)–4533 (X0.45)GainsettingvalueMaster MasterGainamplificationGain settingvalue (scaling)Gain adjustment range (Bayer color)LUT (Lookup Table)The LUT function is used to generate a non-linear mapping between signal values captured on thesensor and those that are output from the camera. You can specify the output curve using 256 settingpoints (indexes).■ To use the LUT functionConfigure the settings as follows.Item Setting value / selectable range DescriptionJAI LUT Mode LUT Use LUT.LUT Selector* R, G, B Select the LUT channel to control.LUT Index SP-12000M-CXP4: 0 to 255SP-12000C-CXP4: 0 to 255Select the LUT index to configure.Indexes represent the possible pixel values captured on thesensor, from the lowest value (Index 0) to the highest (Index255). For example, Index 0 represents a full black pixel andIndex 255 represents a full white pixel.LUT Value 0 to 4095 Set the LUT output value for the selected index.* SP-12000C-CXP4 onlyNoteR, G, and B are configured separately on the SP-12000C-CXP4.■ LUT valuesLUT values range from 0 at the lowest to 4095 at the highest. Linear interpolation is used to calculateLUT values between the index points.