FRLJETYD Operations Manual 29FRL Setup and UseProper setup and use of the FRL unit will ensure accurate results and safe operation. The threecomponents of the FRL must be checked individually to ensure correct operation. Empty the filter reservoir before use. Press the ZERO button on the regulator gauge before setting the operatingpressure. Adjust the lubricator flow properly. Fill the lubricator reservoir with pneumatic tool oil (provided with the FRLunit).Important FRL Operating Procedures Only operate the unit with the air flow moving in the direction indicated bythe arrows on top of the unit. Empty the filter reservoir before each use to remove water and sediment. Fill the lubricator reservoir only with pneumatic tool oil before each use. Adjust the lubricator flow to one (1) drop per ten (10) seconds (shortage oflubrication may cause motor to sieze). Use only the hose provided with the FRL for connection to the unit; a changein hose length may affect tool durability and accuracy.Emptying the Filter ReservoirYou may empty the filter reservoir of water and foreign material in two ways: Emptying water through the release valve on the underside of the reservoir.To use the release valve, push the valve until the water or debris drains out ofthe reservoir. Removal of the reservoir. To remove the reservoir from the FRL unit:a. Push down on the black square button to unlock the reservoir.b. Twist the filter reservoir until the two lines on the FRL body and the filterreservoir are aligned.