49J-30016.0 Circuit Board Diagrams16.1 North American J-335, J-345, J-355, J-365 and J-375Dedicated Power Models (60 Hz)This wiring diagram is used for all North American, 240V (60 Hz)dedicated power models.ORMini-Din Cable providesconstant 12 VAC fromyellow transformer wiresMini-Din ControlPanel CableLight DCU12345678910POWEREXP BAR EXP BARStereoPower SupplyCLEARRAYGRNTB1Standard 240 VAC, 3-Wire Connection (60 Hz, 1-Phase Service)USE COPPER CONDUCTORS ONLY. WIRE SIZE MUST BE APPROPRIATEPER NEC AND/OR LOCAL CODES. THE MAX SUPPLY CONNECTORAMPACITY IS 60A. THE AMPERE RATING OF SUPPLY CONDUCTOROVERCURRENT PROTECTIVE DEVICE IS 60A.REDREDJ6BLKJ5WHTWHTREDBLKBLKWHTBLKRED REDBLK BLKBLK21Hi - limit / freeze sensorTemperature sensorJ1J2J3F130A, 250VSC-30Pump 1CircPumpPump 2Transformer240 VACJ4F1JP142316 58 7HIHILOControl PanelJ20 K1K2K3K4K5K6 K7 K8J21J11J12J13J14J15J16J17J18J19J7 J8 J9 J10This device complies with Part 15 of theFCC rules. Operation is subject to thefollowing two conditions:1. This device may not cause harmfulinterference.2. This device must accept any inteferencereceived including interference that maycause undesired operation.Heater5.5 kW240 VACWHTBLKLED LightingSystem DCUEXTERNAL SERVICE PANELBOX DISCONNECT MEANSMUST BE LOCATED NO CLOSERTHAN 5 FT. (1.52m) FROM THEINSIDE WALLS OF THE SPA ANDWITHIN SIGHT OF SPAMAIN POWERON//OFF SHUTOFFSWITCHLogic Jumper SettingsJP1 1-2 ON = 40A LogicJP1 1-2 OFF = 50A Logic (Factory Default Setting)JP1 3-4 ON = 2 Pump OperationJP1 3-4 OFF = 1 Pump OperationJP1 5-6 ON = 60A Logic (Remove JP1 1-2 Jumper)JP1 5-6 OFF = Leave Off for 40A or 50A LogicJP1 7-8 ON = Celsius Temperature DisplayJP1 7-8 OFF = Fahrenheit Temperature DisplayWHTBLKC(Not offered on all models)(Not offered onall models)Flow sensor(Not offeredon all models)Ports 1-10power spalights, waterfalllights and steplights onapplicablemodels