53LX Collection16.2 Export Models (50 Hz)This wiring diagram is used for all Export 230 VAC 50 Hz spa models.Light DCU12345678910POWEREXP BAR EXP BARBRNBLUCCirc.PumpStereoPower SupplyCLEARRAYGRNTB1BLUBLUJ6BRNJ5BRNBLUBLKBLUBRNBLUBRNBLU BLUBRN BRNBRN21Flow SensorHi - limit / freeze sensorTemperature sensorJ1J2J3F120A, 250VSC-20Pump 1Pump 2Transformer230 VACJ4F1JP142316 58 7HIHILOControl PanelJ20 K1K2K3K4K5K6 K7 K8J21J11J12J13J14J15J16J17J18J19J7 J8 J9 J10Heater2.7 kW @230 VACWHTBLKLED LightingSystem DCULogic Jumper SettingsJP1 1-2 ON = 20A LogicJP1 1-2 OFF = 30A LogicJP1 3-4 ON = 2 Pump OperationJP1 3-4 OFF = 1 Pump OperationJP1 5-6 ON = 40A Logic (Remove JP1 1-2 Jumper)JP1 5-6 OFF = Leave Off for 20A or 30A LogicJP1 7-8 ON = Celsius Temperature DisplayJP1 7-8 OFF = Fahrenheit Temperature DisplayMini-Din Cable providesconstant 12 VAC fromyellow transformer wiresMini-Din ControlPanel CablePorts 1-10power spalights, waterfalllights and steplights onapplicablemodelsOR(not offered onall models)(not offered on all models)(not offered on all models)TB2BRNBLU230 VAC 3-Wire Connection (50 Hz, 1-Phase Service), 1 Pump=15A/21A, 2 Pump=15A/29A,USE COPPER CONDUCTORS ONLY. WIRE SIZE MUST MEET NEC RECOMMENDATONSAND/OR LOCAL CODES AND IS DETERMINED BY MAXIMUM CURRENT DRAW ANDLENGTH OF RUN.