5.2 Winterizing the PumpCAUTIONThe pump must be protected when freezingtemperatures are expected. Allowing the pumpto freeze will cause severe damage and void thewarranty.CAUTIONDo not use antifreeze solutions in the pool,spa, or hot tub systems! Antifreeze is highly toxicand may damage the circulation system. The onlyexception to this is Propylene Glycol. For moreinformation, see your local pool/spa supply store orcontact a qualified swimming pool service company.1. Drain all water from the pump, system equipment,and piping.2. Remove the two (2) drain plugs. Store the drainplugs in a safe location and reinstall them whenthe cold weather season is over. Do not losethe o-rings.3. Keep the motor covered and dry. Do not coverthe pump with plastic, because this will createcondensation that will damage the pump.NOTE Zodiac Pool Systems, Inc. recommends havinga qualified service technician or electricianproperly disconnect the electrical wiring atthe switch or junction box. Once the power isremoved, loosen the two (2) unions and storethe pump indoors. For safety, and to prevententry of contaminants, reinstall all conduit andterminal box covers.4. When the system is reopened for operation,have a qualified technician or electrician makesure all piping, valves, wiring and equipmentare in accordance with the manufacturer’srecommendations. Pay close attention to the filterand electrical connections.5. The pump must be primed prior to starting. Referto Section 4.1, Start-up.Page 16 Jandy ® Pro Series ePump™ Series Pump | Installation and Operation ManualENGLISH