If the flames have yellow tips, loosen the lockingnut and move the bolt in a clockwise direction.WARNINGBurner adjustments should only be performedafter the burners have cooled.Always tighten the locking nut before relightingthe burner.Locking Nut If the flames are making excessive noise or lifting,loosen the locking nut and turn the bolt in a counter-clockwise direction.Remember to tighten the locking nut beforerelighting the burner. If you have any questionsregarding flame stability, please contact customerservice at 1-800-554-5799.Adjustment Bolt1. Specified clearance maintained 24in. fromcombustible materials/construction.2. All internal packaging has been removed.3. The hose and regulator are properlyconnected.INSTALLER FINAL CHECK4. The unit has been tested and is free of leaks.5. The gas supply shut off valve has beenlocated.6. All burners are factory installed.WARNING1. The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the gassupply piping system during any pressure testing of that system at test pressure in excess of ½psi(3.5kpa).2. 2. The outdoor cooking gas appliance must be isolated from the gas supply piping system by closingits individual manual shutoff valve during any pressure testing of the gas supply piping system at testpressure equal to or less ½psi (3.5kpa)9