Jetter AG Programming | 7JXM-HMI User Manual 17 / 227.6 System parametersINFO You can only use the set system parameters after restarting the system.Index Subindex Description Type Dir Defaultvalue0x4556 0 Number of supported en-triesU8 R 43 CAN baud rate:3 = 1 MBaud2 = 500 kBaud1 = 250 kBaud0 = 125 kBaudU8 R/W 14 CANopen® node ID U8 R/W 0x11Tab. 18: System parameters7.7 TroubleshootingEMCY telegrams are sent at startup or after any changes at an inhibit time of 50ms (minimum pause between 2 telegrams). An EMCY telegram is sent when anevent is started or changed.Emergency objecttelegrams (EMCYtelegrams)Byte 0/1 Byte 2 Byte 3-7Emergency Error Code Error registerObject 0x1001Manufacturer specific error fieldAlways 0 is sent.Tab. 19: Bit values of emergency objectsError memory (er-ror history)Code Description0x0000 No error or error reset0x1000 Generic error0x3100 Voltage VBAT_ECU exceeds the permitted limits0x4200 Device temperature is too high0x8110 CAN data overrun (lost objects)0x8140 Recovered from bus-offTab. 20: Emergency Error Codes