Jetter AG Mechanical installation | 4JXM-HMI User Manual 9 / 22➀ JXM-HMI ➁ JVM-104➂ 2 x countersunk screws formounting a RAM Mount ball ➃ Mounting plate with opening forconnector➄8 x screws for fixing the mount-ing plate to the JXM-HMI andJVM-104➅ RAM Mount ball➆ 2 x self-locking nuts1. Screw the desired RAM Mount attachments onto the mounting plate.2. Hold the JXM-HMI and the JVM-104 against the mounting plate from behind.The connectors must be accessible through the openings in the mountingplate.3. Screw the mounting plate onto the JVM-104 and the JXM-HMI.Installing the strainreliefInstall strain reliefs for the connecting cables.■ Ensure that there is sufficient clearance between the strain reliefs and the con-nectors.■ Connectors must not be obstructed, so that they can be removed in the eventof service.4.1.1 Requirements for the installation location■ The installation surface must be level.■ The installation surface should be no more than 5 mm thick.■ The installation location must allow air to circulate.■ The installation compartment must allow adequate air circulation.■ The installation location must be of sufficient size.■ The device must be easily accessible to allow for service work.Space required forinstallation and ser-viceIt must be possible to disconnect the connectors at any time.Avoiding unsuit-able installation lo-cationsThe following installation locations are unsuitable for installation:Unsuitable installation location ReasonOutdoor installation The device must not be exposed to rainor a jet of water. Do not use a steam jetor other such devices to clean the de-vice.This location is not ventilated. The JVM-104 could overheat as heatbuilds up.Installation location close to heat-sensi-tive materialsThe materials could become warped ormisshapen as a result of heat producedby the device.Installation surfaces are uneven. The installation surface could becomemisshapen when fitting the device. Fas-tening is unstable and precarious.