English 5.906-736.0 Rev. 00 (07/15) 51Low-pressure hose drum1 Water supply hose2 Brake leverConnection to an external water supply is established bymeans of the water supply hose DN19, connection, max.length: 30 metresTo unroll or roll up the hose, the brake must be released.For this purpose, open the brake lever in the counter-clockwise direction.NOTEEnsure an even distribution of the hose when rolling it up.Finally lock the hose reel by locking the brake lever in theclockwise direction.1 Ball tap2 Water filter3 Low-pressure hose drumThe inflowing water is freed from rejects by means of a fil-ter prior to further use.In normal operation the ball tap must be set to "operation"(horizontal position).Float container, illustration with dismantled liquid softenercontainer1 Filler neck2 Swimmer ball3 Water inletNOTEThe filling level indicator does not show the water level inthe float container, but the level in the two 250 l watertanks.Float tankThe float container is integrated in the left water tank. It islocated underneath the liquid softener tank.The swimmer reservoir supplies the pump evenly with wa-ter. It is also used to separate the water inlet and the pumpand prevents detergent from entering the water supply linein case of damage.The filling of the two 250-litres water tanks also takes placethrough the float container.Float valvesWater flows into the float container through the two openedfloat valves.When the water level is rising, the relevant float ball risesand closes the associated float valve.The float valve is adjusted permanently and must not bereadjusted.Due to the high volume flow of up to 1700 l/h, two floatvalves are necessary.9.9 Water inlet9.10 Swimmer tank