GB - 68Operation of the Unit4.1.4 Remote controlFor remote control of the KEB COMBIVERT F5 a special HSP5 operator is available.Operator Cable The last three digits of the part number indicate thelength of the cable in dm.00F5060-9000 00F50C0-2xxx00F5060-9001 00F50C0-3xxx4.1.5 Other operatorsIn addition to the described operators the KEB COMBIVERT can be equipped with furtheroperators for special applications (Profibus, Interbus, Sercos, CAN, DeviceNet). You findfurther information on that on our home page.4.2 Keyboard Operation4.2.1 Parameter numbers and valuesWhen switching on KEB COMBIVERT F5 the value of parameter CP.1 appears.The function key changes between the parametervalue and parameter number.FUNC.SPEEDWith UP (▲) and DOWN (▼) the value of theparameter number is increased/decreased withchangeable parameters.STARTSTOPSTARTSTOPPrincipally during a change, parameter values are immediately accepted and stored non-volatile. However, with some parameters it is not useful that the adjusted value is acceptedimmediately. In these cases the adjusted value is accepted and stored non-volatile bypressing ENTER. When this type of parameter is changed a point appears behind thelast digit.By pressing „ENTER“ the adjusted value isaccepted and non-volatile stored.ENTERF/R235237RS232-cable 3mPC / OperatorPart number 00.58.025-001D9-pole SUB-D connectorF5-OperatorHousing (PE)9 pole SUB-D femalePC